4 floors · 35 apartments · 44,500 sq ft · built 1930 · class C7 · owner of record: La Croes Equity Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 61 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 44,500 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 182 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 182 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 305 days | Registered through 2027-09-01 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-05 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 15, 2017 | Construction CLASS - 2 WORK W/O A PERMIT. NOTED: AT 3RD STORY APT. 2B N-W SECTION OF BLDG, APT. LAYOUT CHANGE, PARTITION & DOOR INSTALLED TO CREATE NEW ROOMS TO BEUSED AS SROS,NO LIVING ROOM SPACE. REMEDY: OBTAIN PERMIT OR RESTORE TO #35245153Y | Jun 21, 2017 IN VIOLATION | $0 |
| Apr 8, 1996 | Boilers Non-Hazardous 3-A-B,6-A,21-C,25A-B,32-A,48-A,49,51.A HART FORD LOOP LEAKING B-NO ANTISYPHON ON OIL LINE C-OIL RETURN LINE NOT PIPED PROPERLY AT TANK.D-REMOVE FLU PIPE FROM 2ND DISCONECTED #32013117P | Aug 9, 1996 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2023 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2300901 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #35368 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #14390 | DOB VIOLATION - ACTIVE |
| Jan 1, 2009 | LOCAL LAW 62/91 - BOILERS #06954 | DOB VIOLATION - ACTIVE |
| Feb 3, 2006 | IMMEDIATE EMERGENCY #19/06 | DOB VIOLATION - ACTIVE |
| Mar 28, 1997 | CONSTRUCTION #91AA | DOB VIOLATION - ACTIVE |
| Apr 30, 1996 | IMMEDIATE EMERGENCY #73/96A | DOB VIOLATION - ACTIVE |
| Apr 30, 1996 | IMMEDIATE EMERGENCY #73/96A | DOB VIOLATION - ACTIVE |
| Apr 10, 1996 | EMERGENCY #73/96 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2023 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jan 1, 2009 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 21, 2025 | C | Apt 10A · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Aug 14, 2025 |
| Jul 18, 2025 | A | Apt 10A · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RADIATOR FROM NORTH AT EAST WALL, 1st RISER FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 10A, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 21, 2025 |
| Jul 18, 2025 | A | Apt 10A · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FROM NORTH AT EAST WALL, 1st DOOR FRAME FROM NORTH AT EAST WALL, 1st DOOR FROM SOUTH AT WEST WALL IN THE FOYER LOCATED AT APT 10A, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 21, 2025 |
| Jul 18, 2025 | A | Apt 10A · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RADIATOR FROM NORTH AT EAST WALL, 1st RISER FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 10A, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 21, 2025 |
| Jul 7, 2025 | C | Apt 10A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 10A, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM EAST AT SOUTH | Aug 2, 2025 |
| Jun 12, 2025 | B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Jul 17, 2025 |
| May 30, 2025 | B | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING BENT DROP LADDER AT BUILDING FRONT AT 2nd FIRE ESCAPE FROM NORTH AT WEST, 2nd STORY | Jul 4, 2025 |
| Oct 23, 2023 | C | Apt 6A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 18, 2023 |
| Oct 23, 2023 | C | Apt 6A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 18, 2023 |
| Oct 23, 2023 | B | Apt 6A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 27, 2023 |
| Oct 23, 2023 | B | Apt 6A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 27, 2023 |
| Oct 23, 2023 | B | Apt 6A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 27, 2023 |
| Oct 23, 2023 | B | Apt 6A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 27, 2023 |
| Oct 23, 2023 | B | Apt 6A · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 27, 2023 |
| Oct 23, 2023 | B | Apt 6A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST AT CENTER LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 27, 2023 |
| Oct 23, 2023 | B | Apt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW LOWER SASH COUNTER BALANCE IN THE 1st ROOM FROM EAST AT CENTER LOCATED AT APT 6A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 27, 2023 |
| Oct 6, 2023 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HEAVY DUTY MORTISE LOCK AND ASSEMBLY AT DOOR AT STREET TO PUBLIC HALL AT PUBLIC HALL, 1st STORY | Oct 12, 2023 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 31, 2026, 12:07 AM ET. BBL 2037230048.