Brooklyn · Block 3079 · Lot 25 · 11206

109 Graham Avenue

3 floors · 4 apartments · 4,500 sq ft · built 1931 · class C3 · owner of record: 109 Graham Ave Brooklyn Llc

8open violations
$15,060ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2025-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 56 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 72 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 787 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-01 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4) · $15,060 owed
IssuedViolationHearingBalance
Oct 3, 2025Construction CLASS - 1
WORK WITHOUT A PERMIT. NOTED: AT THE 1ST FLOOR COMMERCIAL SPACE AT THERIGHT REAR STORAGE AREA. INSTALLED FULL HEIGHT PARTITIONS WITH A DOOR TO CREATE A SLEEPING AREA. THERE ARE NO PERMITS ON FILE FOR THIS WORK.
#35667887N
Oct 5, 2026
DEFAULT
$2,530
Oct 3, 2025Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O OR DEPARTMENT RECORDS. NOTED: AT RIGHT REAR STORAGE AREA OF THE 1ST FLOOR COMMERCIAL SPACE. OBSERVED A ROOM APPROX. 5' WX9'L CREATE FOR SLEEPING AREA WITH BUD AND TV
#35667886L
Oct 5, 2026
DEFAULT
$12,530
Jan 4, 2024Plumbing CLASS - 2
AS PER PROVISION OF LAW 28-301.1 FAILURE TO MAINTAIN GAS PIPING IN A COMPLIANT MANNER. PROHIBITED FLEXIBLE CONNECTORS USED TO CONNECT TWO DEEP FRYERS AS PER FGC 411., REMOVE NON-COMPLYING MATERIAL OR EQUIPMENT;
#39102715Y
Dec 4, 2025
DEFAULT
$0
Dec 2, 2008Boilers CLASS - 3
B354,16,24A,32A,34B,36,40,50,50A,50B,50C,50D,50E,50F,50G. 50 INSUFFICIENT FRESH AIR INTO BOILER ROOM ALSO MISSING FIRE DAMPER 50A MISSING 530C (UMUE) 50B MISSING CLEAN OUT TEE FOR PRESTROLS 50C MISSING AIR GAP
#32065202Y
Oct 4, 2010
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (4) · C 0 · B 4 · A 0
IssuedClassViolationCorrect by
Apr 15, 2009BApt 2L · SECTION 27-2089 ADM CODE THE PREMISES FORMERLY A VACANT BUILDING ARE NOW OCCUPIED BY OTHER THAN A CARETAKER WITHOUT OBTAINING A CERTIFICATE OF OCCUPANCY .. LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTMay 20, 2009
Jul 1, 2008BApt 2L · D26-35.01 ADM CODE THE PREMISES FORMERLY A VACANT BUILDING ARE NOW OCCUPIED BY OTHER THAN A CARETAKER WITHOUT OBTAINING A CERTIFICATE OF OCCUPANCY 2 STY WEST APT 2L. LOCATED AT APT 2LAug 5, 2008
Sep 10, 2007BApt 3L · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 15, 2007
Sep 10, 2007BApt 3L · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 15, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 9:25 PM ET. BBL 3030790025.

Look up another building