Bronx · Block 2700 · Lot 38 · 10459

1082 Hall Place

4 floors · 8 apartments · 5,909 sq ft · built 2019 · class C1 · owner of record: 1082 Hall Am Llc

32open violations
$107,900ECB/OATH penalties owed
7HPD class C (immediately hazardous)
69dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 313 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1165 days
Next cycle year 2029

Open violations

ECB / OATH (17) · $107,900 owed
IssuedViolationHearingBalance
Mar 23, 2021Site Safety CLASS - 1
DOCUMENTS TO BE KEPT ONSITE.SWS DRAWING AT THE TIME OF MY INSPECTION AT A 4 STORY BUILDING UNDER CONSTRUCTION I OBSERVED SIDEWALK SHED IN PLACE AT EXP#1.REQUEST TO SEE THE SWS DRAWING.NONE WAS PROVIDE INSPECTIO
#35550803H
Jun 18, 2021
DEFAULT
$6,250
Mar 23, 2021Construction CLASS - 1
3309.10 ROOF PROTECTION-ADJACENT PROPERTY AT THE TIME OF MY INSPECTIONAT A 4 STORY BUILDING UNDER CONSTRUCTION I OBSERVED CONSTRUCTION OPERATIONS ALSO INADEQUATE ROOF PROTECTION FOR ADJACENT PROPERTY EXPO 2 & 4
#35550804J
Jun 18, 2021
DEFAULT
$6,250
Mar 23, 2021Construction CLASS - 1
INADEQUATE HOUSEKEEPING AT THE TIME OF MY INSPECTION AT A 4 STORY BUILDING UNDER CONSTRUCTION I OBSERVED INADEQUATE HOUSEKEEPING AT EXPO 3 MULTIPLE DEBRIS AND GARBAGE IS PILLED UP AND SCATTER AT EXPO 3 MAKE IT
#35550806N
Jun 18, 2021
DEFAULT
$6,250
Mar 23, 2021Construction CLASS - 2
STORAGE ON SHED AT THE TIME OF MY INSPECTION AT A 4 STORY BUILDING UNDER CONSTRUCTION I OBSERVED THE SWS IN PLACE AT EXPO 1 AFTER INSPECTINGTHE SWS I OBSERVED CONSTRUCTION EQUIPMENT DEBRIS AND BRICKS ON THE SWS
#35550805L
Jun 18, 2021
DEFAULT
$5,000
Nov 9, 2020Construction CLASS - 2
PROJECT INFORMATION PANEL/SIDEWALK SHED PARAPET PANEL NOT PROVIDED.NOTED:AT THE TIME OF MY INSPECTION OF 4 STORY NEW BUILDING CONSTRUCTION JOBSITE I OBSERVED MISSING PROJECT INFORMATION PANEL AND MISSING SIDEWA
#35540027P
Jan 29, 2021
DEFAULT
$3,125
Mar 20, 2020Site Safety CLASS - 1
NO SUPERINTENDENT/NO COMPETENT PERSON FAILURE TO PERFORM THEIR DUTIES ON ACTIVE JOB SITE.AT THE TIME OF INSPECTION AT A 4 STORY NB,I OBSEVEDMANY UNSAFE CONDITIONS ON SITE.LOGS WERE NOT SIGN FOR OVER 2 MONTHS BY
#35479149N
Sep 10, 2021
DEFAULT
$12,500
Mar 20, 2020Construction CLASS - 1
PROTECTION OF ROOF(NEIGHBORING PROPERTIES)AT THE TIME OF INSPECITON ATA 4 STORY NB,I OBSERVED ON THE ROOF LEVEL EXPO 2&4 MP ROOF PROTECTION ON NEIGHBORING PROPERTIES AND PARAPET WALL & FACADE WAS NO COMPELLED O
#35480002R
Aug 13, 2021
DEFAULT
$6,250
Mar 20, 2020Construction CLASS - 2
BC33149-SUPPORTED SCAFFOLD SHALL MEET ITS REQUIREMENTS PER SECTION 3314.9.1 THRU 3314.9.4.AT THE TIME OF INSPECTION AT A 4 STORY NB,I OBSERVED ON A ACTIVE JOB SITE FACADE WORK IN PROGRESS WORKERS WORKING ON A S
#35480003Z
Aug 13, 2021
DEFAULT
$3,125
Mar 20, 2020Construction CLASS - 1
FAILURE TO INSTITUTE SAFETY MEASURE/EQUIPMENT ON ACTIVE JOB SITE/CONSTRUCTION-NO GUARD RAILS.AT THE TIME OF INSPECTION AT A 4 STORY NB,I OBSERVED THE GROUND 2ND-3RD-4TH FLOOR MISING GUARD RAILS ON WINDOW AND LE
#35480001P
Aug 13, 2021
DEFAULT
$12,500
Mar 20, 2020Construction CLASS - 1
FAILURE TO INSTITUTE SAFETY MEASURES-EGRESS AND HOUSEKEEPING ON ACTIVECONSTRUCTION SITE.AT THE TIME OF INSPECTION OF A 4 STORY NB,I OBSERVEDMANY VIOLATING CONDITIONS ALL OVER JOB SITE ALL EXPO'S.TEMPORARY WOODE
#35480000N
Jul 9, 2021
DEFAULT
$12,500
Dec 12, 2019Site Safety CLASS - 1
COMPETENT PERSON NOT ON SITE @TIME OF AN ACTIVE JOBSITE W/APPROX 7 WORKERS ON SITE INSTALLING THE SIDEWALK SHED & INSTALLING OPEN WEB JOIST WITHIN THE SITE, I REQUESTED FROM A WORKER WITH THE SITE FOR THE COMPE
#35464054Z
Jan 31, 2020
DEFAULT
$12,500
Oct 23, 2019Construction CLASS - 2
LACK OF EGRESS.AT TIME OF INSPECTION I OBSERVED AN ACTIVE CONSTRUCTIONSITE WITH EXCAVATION BACKFIELD & REBAR ON PROGRESS,DURING INSPECTION NOTED THE JOBSITE DONT HAVE ANY EGRESS FOR PUBLIC.DOB INSPECTOR & WORKE
#35456743Y
Dec 20, 2019
IN VIOLATION
$5,000
Oct 23, 2019Construction CLASS - 2
JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBJECTION"INADAQUATE".AT TIME OF INSPECTOIN I OBSERVED AN ACTIVE CONSTRUCTION SITEWITH EXCAVATION & REBAR WORK ON PROGRESS,DURING INSPECTION NOTED AT EX
#35456746J
Dec 20, 2019
IN VIOLATION
$400
Oct 23, 2019Construction CLASS - 1
NO GUARD RAILS.AT TIME OF INSPECTION I OBSERVED AN ACTIVE CONSTRUCTIONSITE WITH EXCAVATION & BACKFILL ON PROGRESS,DURING INSPECTION I OBSERVED WORKER DOING BACKFILL AND NO GUARD RAILS SYSTEM INSTALL TO PREVENT
#35456744X
Dec 20, 2019
IN VIOLATION
$2,500
Oct 23, 2019Construction CLASS - 1
UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT.AT TIME OF INSPECTION I OBSERVED AN ACTIVE CONSTRUCTION SITE WITH EXCAVATION & BACKFILLWORK ON PROGRESS,DURING INSPECTION I OBSERVED 6 PLASTIC CONTAINER WITH
#35456745H
Dec 20, 2019
IN VIOLATION
$2,500
Oct 23, 2019Site Safety CLASS - 1
FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33."SITE SAFETY PLANS"AT TIME OF INSPECTION I OBSERVED AN ACTIVE CONSTRUCTION SITE WITH EXCAVATION WORK"P"BACKFIL WORK ON PROGRRESS,DURING IN
#35456741K
Dec 20, 2019
IN VIOLATION
$1,250
Oct 23, 2019Site Safety CLASS - 1
CONSTRUCTION SUPERINTENDENT FIALED TO PERFORM DUTIES AS PER RULE.AT TIME OF INSPECTION I OBSERVED ACTIVE CONSTRUCTION SITE WITH EXCAVATION AND BACKFILL WORK ON PROGRESS,DURING INSPECTION I ASKED FOR SUPERINTEND
#35456742M
Feb 14, 2020
IN VIOLATION
$10,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (32) · C 7 · B 13 · A 12
IssuedClassViolationCorrect by
Sep 14, 2026A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT PUBLIC HALL, 1st STORYDec 18, 2026
Sep 14, 2026A§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX SIGNAGE MISSING AT PUBLIC HALL, 1st STORYDec 18, 2026
Sep 14, 2026B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SENSOR AT CEILING LIGHT FIXTURES AT PUBLIC HALL STAIRS, 1st STORYOct 19, 2026
Sep 14, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORYSep 28, 2026
Sep 14, 2026A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYDec 18, 2026
Sep 14, 2026BApt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st BATHROOM FROM NORTH AT EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOct 19, 2026
Sep 14, 2026CApt 1A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOct 10, 2026
Sep 14, 2026B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOTION SENSOR AT CEILING LIGHT FIXTURES AT PUBLIC HALL, 1st STORYOct 19, 2026
Sep 14, 2026A§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS SIGNAGE MISSINGDec 18, 2026
Sep 14, 2026C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGNAGE MISSING AT PUBLIC HALL, 1st STORYSep 20, 2026
Sep 14, 2026BApt 1A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING AND BEHIND WEST WALL IN THE 1st BATHROOM FROM NORTH AT EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOct 19, 2026
Sep 14, 2026BApt 2B · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOct 19, 2026
Sep 14, 2026BApt 2B · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOct 19, 2026
Sep 14, 2026AApt 2B · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN AT WEST WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTDec 18, 2026
Sep 14, 2026CApt 2B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOct 10, 2026
Aug 3, 2026A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH WALL AT PUBLIC HALL, 1st STORYNov 6, 2026
Aug 3, 2026BApt 3B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO PANEL IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 1st STORYSep 7, 2026
Aug 3, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AT FIRE RETARDANT MATERIAL AT SOUTH WALL AT PUBLIC HALL, 1st STORYSep 7, 2026
Mar 5, 2026AApt 2B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING IN THE 1st ROOM FROM EAST AT CENTER LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJun 8, 2026
Mar 5, 2026BApt 2B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTApr 9, 2026
Mar 5, 2026BApt 2B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTApr 9, 2026
Mar 5, 2026CApt 2B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTMar 31, 2026
Mar 5, 2026AApt 2B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJun 8, 2026
Mar 5, 2026AApt 2B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJun 8, 2026
Mar 5, 2026AApt 2B · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN AT WEST WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJun 8, 2026
Mar 5, 2026AApt 2B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJun 8, 2026
Mar 5, 2026AApt 2B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJun 8, 2026
Aug 18, 2025CApt 1B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 13, 2025
Aug 18, 2025BApt 1B · § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT CEILING LIGHT FIXTURE IN THE 2nd ROOM FROM EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 22, 2025
Aug 18, 2025CApt 1B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 13, 2025
Apr 30, 2025BApt 1A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHJun 4, 2025
Apr 30, 2025BApt 1A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHJun 4, 2025

Issued in the last 120 days

DateSourceWhatNow
Sep 14, 2026HPD A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD A§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX SIGNAGE MISSING AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SENSOR AT CEILING LIGHT FIXTURES AT PUBLIC HALL STAIRS, 1st STORYOpen
Sep 14, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st BATHROOM FROM NORTH AT EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 14, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 14, 2026HPD B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOTION SENSOR AT CEILING LIGHT FIXTURES AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD A§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS SIGNAGE MISSINGOpen
Sep 14, 2026HPD C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGNAGE MISSING AT PUBLIC HALL, 1st STORYOpen
Sep 14, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING AND BEHIND WEST WALL IN THE 1st BATHROOM FROM NORTH AT EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 14, 2026HPD B§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Sep 14, 2026HPD B§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Sep 14, 2026HPD A§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN AT WEST WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Sep 14, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Aug 3, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH WALL AT PUBLIC HALL, 1st STORYOpen
Aug 3, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO PANEL IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 1st STORYOpen
Aug 3, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AT FIRE RETARDANT MATERIAL AT SOUTH WALL AT PUBLIC HALL, 1st STORYOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 4:18 PM ET. BBL 2027000038.