Manhattan · Block 814 · Lot 46 · 10018

108 West 39 Street

16 floors · 118,949 sq ft · built 1927 · class O6 · owner of record: 10839 Assoc

26open violations
$5,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
99dto Facade inspection report (Cycle 10A)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $636,500 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 99 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 118,949 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 814). Agency page

Dec 31, 2034
in 2969 days
Next due 2034

Open violations

ECB / OATH (13) · $5,000 owed
IssuedViolationHearingBalance
Jun 17, 2024Construction CLASS - 2
A.C. 27.929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY AREGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FEET OR MORE
#37028778X
Oct 31, 2024
IN VIOLATION
$0
Dec 9, 2022Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#901931.REMEDY:SUBMIT ACCEPTABLE REQUIRE
#37024582X
Mar 2, 2023
ADMIT/IN-VIO
$0
Nov 1, 2021Construction CLASS - 2
27-929.1 AC27-929.1,FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OFAUTOMATIC SPRINKLERS&FILE FINAL SPRINKLER REPORT PREPARED BY REGISTERED DESIGN PROFESSIONAL IN OFFICE BLDG 100' OR MORE IN HT IN EXISTENCE O
#37022577M
Mar 17, 2022
IN VIOLATION
$0
Mar 30, 2021Construction CLASS - 2
27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FEET OR MORE IN HE
#37021005M
Jul 8, 2021
DEFAULT
$0
Feb 12, 2020Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.NOTE:AT TIME OF MY INSPECTION ON A COMPLAINT THAT A VEHICLE HIT THE SIDEWALK SHED A 16 STORY BULDING I OBSERVED THE SIDEWALK SHED VERTICAL MEMBER STEEL CO
#35471845K
May 27, 2021
DEFAULT
$5,000
Nov 15, 2019Construction CLASS - 2
27-929.1 A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BUILDIN
#37016201N
Feb 13, 2020
IN VIOLATION
$0
Jun 20, 2017Unknown CLASS - 2
FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000003111 HASBEEN INSPECTED,TESTED AND DISINFECTED,AND THAT A MAINTENANCE PLAN HAS BEEN DEVELOPED AND IMPLEMENTED,BY NOVEMBER,1,2016.REM:FILE ANNUAL CERT
#37002310P
Aug 31, 2017
IN VIOLATION
$0
Oct 30, 2015Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING NORTH ELEV EXP1-TERRA COTTA.DECORATIVE COLUMNS,COPING,TRIM CRACKED AND MORTAR JOINTS ERODED. BRICK SPALLING AND STEP CRACKS (IE 13-14 FL VERTICAL) CRACK IN BRICK EAST ELEV
#35133772R
Dec 31, 2015
STIPULATION/IN-VIO
$0
Aug 31, 2015Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES.NOED (I) AT EXP2 (EAST ELEVATION A BAND OF UNSTABLE MASONRY AT SPANDREL BETWEEN FLOORS 7 AND 8 NEAR WINDOW LINE 1 FROM NORTHEAST CORNER; II-AT EXP4 (WEST ELE
#35133481R
Oct 15, 2015
ADMIT/IN-VIO
$0
May 27, 2009Unknown CLASS - 2
SEC. BC3314.1.0.1 INSTALLED EQUIPMENT DOES NOT MATCH APPROVED PLANS/DRAWINGS. WORK CONTRARY TO DEPT OF BUILDINGS APPROVED PLANS & APPLICATIONS. NOTED: WIRE ROPE JUMP OVER 2 SETBACKS MISSING THIMBLES.
#34765393X
Jul 24, 2009
IN VIOLATION
$0
Feb 7, 2007Construction Non-Hazardous
EXIT PASSAGE OR CORRIDOR.REQUIRED WIDTH DECREASED BY OBSTRUCTION NOTEDAT SOUTH EAST CORNER EXIST AN NORTH VERTICLE EXIT PASSAGEWAY WITH NUM EROUS BOXES,CRATES,ETC.REMEDY:REMOVE ALL OBSTRUCTION & MAINTAIN
#34543523L
Mar 30, 2007
IN VIOLATION
$0
Feb 7, 2007Public Assembly Non-Hazardous
PLACE OF ASSEMBLY CONTRARY TO APPROVED PLANS NOTE:PA PLANS DATED MAY 18, 1993 PA 36/85(PA.1)INDICATES(15) 4 SEAT TABLES AS WELL AS (9) 2 SEAT TABLES & (7) SEATS AROUND BAR AT 1ST FLOOR HAS NOW BEEN ILLEGAL
#34543522J
Mar 30, 2007
IN VIOLATION
$0
Feb 7, 2007Public Assembly Non-Hazardous
PANIC HARDWARE IN PLACE OF ASSEMBLY INOPERATIVE NOTE:AT CELLAR LEVEL EXIT DOOR PANIC BAR IS INADEQUATE. REMEDY:REPAIR OR REPLACE PANIC HARDWARE LATCHING SYSTEM.
#34543521H
Mar 30, 2007
IN VIOLATION
$0
DOB (8)
IssuedViolationStatus
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00196
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2100344
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2000445
DOB VIOLATION - ACTIVE
Sep 3, 2019SPRINKLER
FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019
#NRF00974
DOB VIOLATION - ACTIVE
May 19, 2019CONSTRUCTION
DAMAGE OBSERVED TO HAVE BEEN SUSTAINED DUE TO WORK IN KITCHEN OF CHINESE RESTAURANT AT 1ST FLOOR DUE TO FIRE
#CNE01GS
DOB VIOLATION - ACTIVE
Jul 8, 2013ELEVATOR

#9028/472725
DOB VIOLATION - ACTIVE
Feb 7, 2007PUBLIC ASSEMBLY

#MTF04EM
DOB VIOLATION - ACTIVE
Oct 25, 2006CONSTRUCTION

#MTF01RNS
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Sep 3, 2019Sprinklers FTF-SP-FINAL
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 7:20 PM ET. BBL 1008140046.