Manhattan · Block 1908 · Lot 37 · 10027

108 West 124 Street

5 floors · 10,320 sq ft · built 1910 · class N2 · owner of record: Jewish Board Of Family And Children'S Se Rvices Inc

20open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
778dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-30 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Mar 22, 2019Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY. NOTED: ASPER C/O#107837 ISSUED AFTER VCOMPLETION OF ALT-1 JOB#100510136 THE BLDG SHOULD BE OCCUPIED W/1 APT AT THE 1ST STY,FROM 2ND STY TO 5TH STY 2
#35373413H
May 16, 2019
IN VIOLATION
$0
DOB (6)
IssuedViolationStatus
Sep 6, 2019(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
#10129
DOB VIOLATION - ACTIVE
Sep 15, 2017ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST
#05834
DOB VIOLATION - ACTIVE
Jan 3, 2017(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
#11534
DOB VIOLATION - ACTIVE
Nov 14, 2016(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
#12619
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#13368
DOB VIOLATION - ACTIVE
Apr 21, 1991CONSTRUCTION

#NEAC01
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (10)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Sep 6, 2019Elevators ACC1
Active
May 20, 2019Elevators EVCAT5
Active
Sep 15, 2017Elevators EVCAT1
Active
Jan 3, 2017Elevators ACC1
Active
Nov 14, 2016Elevators ACC1
Active
Aug 29, 1995Boiler LL6291
Active
HPD (3) · C 0 · B 3 · A 0
IssuedClassViolationCorrect by
Apr 15, 2013BApt 36 · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ROOM LOCATED AT B-ROOM 36, 4th STORY, 5th B-ROOM FROM WEST AT NORTHMay 20, 2013
Dec 27, 2011BApt 51 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ROOM LOCATED AT B-ROOM 51, 5th STORY, 5th B-ROOM FROM NORTH AT EAST , SECTION AT EASTJan 31, 2012
Dec 27, 2011BApt 51 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ROOM LOCATED AT B-ROOM 51, 5th STORY, 5th B-ROOM FROM NORTH AT EAST , SECTION AT EASTJan 31, 2012

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 6:56 PM ET. BBL 1019080037.