Brooklyn · Block 1600 · Lot 6 · 11221

1076 Broadway

4 floors · 4 apartments · 6,814 sq ft · built 2005 · class C9 · owner of record: 1076ny Llc

24open violations
$9,415ECB/OATH penalties owed
7HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 70 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 86 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 801 days
Next cycle year 2028

Open violations

ECB / OATH (3) · $9,415 owed
IssuedViolationHearingBalance
Mar 2, 2021Boilers CLASS - 2
BAXI BOILER LOCATED IN APT 2B=BOILER THERMOSTAT IS DEFECTIVE NO HEAT IN APT FROM THE BOILER/ INSUFFICIENT HOT WATER IN THE APT FROM THE BOILER/ STORAGE IN THE BOILER ROOM/, MAINTAIN BOILER; CORRECT VIOLATION AN
#39036973Y
Jul 7, 2021
ADMIT/IN-VIO
$0
Jul 10, 2019Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35347343M ISSUED ON 08/01/18,AND TO FILE A CERTIFICATE OF PURSUANT TO 28-201.1 AND 1RNCY 102-01(D)(2).AN ACCEPTIBLE CERTIFICATE HAS
#37015382R
Dec 9, 2019
DEFAULT
$9,415
Aug 1, 2018Construction CLASS - 3
WORK W/O A PERMIT: WORK NOTED: FRONT FACADE FIRST FLOOR ERECTED BUSIN ESS ACCESSORY SIGN AWNING APPRX 5'H X 80'W WRAPPING AROUND NORTH AND WEST SIDE OF BUILDING (EXP #1 AND 4), WORDING "DELI & GROCERY 1076 BROA
#35347343M
Nov 19, 2018
STIPULATION/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (21) · C 7 · B 12 · A 2
IssuedClassViolationCorrect by
Dec 17, 2024B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOORJan 21, 2025
Dec 16, 2024C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BASEMENT AT BOILER ROOMDec 22, 2024
Dec 16, 2024CApt 3A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 30, 2024
Dec 16, 2024CApt 3A · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 14, 2024
Jun 4, 2024BApt 3A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6 SQ FT AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 16653872 ISSUED 04-FEB-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017Jul 9, 2024
Feb 12, 2024C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ENTRANCE DOOR TO PUBLIC HALL AT BUILDING FRONT AT PUBLIC HALL, 1st STORYFeb 26, 2024
Feb 12, 2024C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BULKHEAD DOOR TO ROOFFeb 26, 2024
Feb 12, 2024B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS AT SKYLIGHT AT BULKHEADMar 18, 2024
Oct 11, 2023BApt 3A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 15, 2023
Oct 11, 2023CApt 3A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 25, 2023
Mar 17, 2021A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTEDJun 20, 2021
Mar 17, 2021BApt 2B · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTApr 21, 2021
Mar 8, 2021A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTEDJun 11, 2021
Sep 6, 2017BApt 3A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ....DEFECTIVE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 11, 2017
Sep 6, 2017BApt 3A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ...DEFECTIVE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 11, 2017
Sep 6, 2017BApt 3A · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .... IN THE ENTRANCE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 11, 2017
Mar 28, 2016BApt 2B · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 2, 2016
Mar 28, 2016BApt 2B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 2, 2016
Jul 20, 2015BApt 3B · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 3B, 3rd STORY, APARTMENT AT SOUTHAug 24, 2015
Jul 20, 2015BApt 3B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 3B, 3rd STORY, APARTMENT AT SOUTHAug 24, 2015
Sep 11, 2014CApt 4A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORYSep 9, 2014

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 9:41 PM ET. BBL 3016000006.