1 floors · 33,684 sq ft · built 1930 · class E1 · owner of record: Jamaica Commercial Properties
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 57 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 33,684 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 178 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 178 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 422 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 28, 2015 | Construction CLASS - 3 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.NOTED 1 ROOF AC UNIT CABLE#MEA INFORMATION MISSING,UNIT IS NOT ATTACHED TO DRAINAGE& NOT INSTALLED VIBRATION ISOLATORS @ EACH CORNER OF THE UNIT AS SHOWN #35135619J | Dec 15, 2015 IN VIOLATION | $0 |
| Apr 3, 2007 | Construction Non-Hazardous WORK W/O PERMIT. WORK NOTED: AT 1ST LEVEL CREATED COFFEE SHOP; INSTALLED WATER & WASTE LINES FOR A COMMERCIAL SINK; ALSO INSTALLED 240 VOLT ELECTRIC LINE FOR ELECTRIC COOKING EQUIPMENT. REMEDY: OBTAIN PERMIT OR #34571827Z | Oct 28, 2008 IN VIOLATION | $0 |
| Apr 3, 2007 | Quality of Life Hazardous OCCUPANCY CONTRARY TO CERTIFIED OCCUPANCY. C.O #Q 189427 INDICATES PREMISES TO BE A FACTORY; FOR CHEMICAL COMPOUND & PACKING WAREHOUSE. ILLEGAL OCCUPANCY NOTED: FACTORY CONVERTED TO COFFEE SHOP W/ KITCHEN SINK, #34571826R | Oct 28, 2008 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 21, 2020 | CONSTRUCTION STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION, DAMAGE OBSERVED TO HAVE BEEN SUSTAINED TO CINDER BLOCK WALL IN THE CORNER OF EXPO # 02 & 03 DUE TO CAR IMPACTED AT 107-15 180 STREET QN. A PARTIAL VACATE ORDER ISSUED INTERIOR AND EXTERIOR SIDE 20'-0" AROUND FROM CAR IMPACTED DAMAGED WALLS. #20-00220 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 4, 2026, 12:48 AM ET. BBL 4103430256.