2 floors · 2 apartments · 2,560 sq ft · built 1910 · class S2 · owner of record: Sadoo Real Estate Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 63 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 307 days | Registered through 2027-09-01 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 8, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED AT CELLAR LEVEL CREATED CLASS "A" APARTMENT WITH BEDROOMS, 3 PIECE BATHROOM AND KITCHEN W/GAS STOVE. REMEDY: DISCONTINUE ILLEGAL USE. #35685952J | Nov 10, 2026 | $1,250 |
| Feb 8, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED AT CELLAR LEVEL FULL HEIGHT PARTITIONS CREATING MULTIPLE ROOMS ALONG WITH 3 PIECE BATHROOM AND KITCHEN WITH GAS STOVE INCLUDING ALL PLUMBING(GAS AND WATER) AND ELECTRICAL COMPONEN #35685953L | Nov 10, 2026 | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Feb 8, 2026 | CONSTRUCTION STRUCTURE RENDERED NON COMPLIANT AT TIME OF INSPECTION OBSERVED SMOKE , FIRE AND WATER DAMAGE THROUGHOUT . MUTLIPLE SKYLIGHTS REMOVED AND OP EN TO THE LEEMNTS . WINDOWS AND DOORS OUT DUE TO FIRE . VACATE ENTIRE BUILDING STRUCTURE MUST BE MAINTIAN IN A CODE COMPLIANT MANNER #CER01CR | DOB VIOLATION - ACTIVE |
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Jul 8, 2026 | DOB Safety | Structurally Compromised Buildings: Report due for structurally compromised property | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 29, 2026, 8:12 AM ET. BBL 4094250008.