1.5 floors · 16,700 sq ft · built 1931 · class F9 · owner of record: Kings Family Services, Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 787 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 9, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS 39109694X., FILE A CERTIFICATE OF CORRECTION #39183972M | Jul 17, 2026 DEFAULT | $6,250 |
| Apr 9, 2026 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER FOR SUMMONS 39102645H., COMPLY WITH COMMISSIONER'S ORDER #39183971K | Jul 17, 2026 DEFAULT | $12,500 |
| Mar 22, 2024 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. NOTED: AT TIME OF INSPECTION 3 WORKERS WERE OBSERVED AT PREMISES: (1) INSTALLING WOOD BRACES AT ROOF FOR STABILIZATION & OTHERS REMOVING BRICK DEB #39109694X | Apr 21, 2025 IN VIOLATION | $5,000 |
| Jan 3, 2024 | Construction CLASS - 1 THE SOUTH WEST CORNER OF THE ROOF MATERIALS ABOVE EXPOSURE #2 AND #3 WALL REMOVED / DEMOLISHED APPROXIMATELY 25 FEET BY 25 FEET (625 SQ FT). THE STRUCTURAL INTEGRITY OF THE ROOF AND FREE STANDING WALLS MAY BE C #39102645H | Sep 12, 2025 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Dec 6, 2023 | CONSTRUCTION VACATE/EMERGENCY WORK ORDER.ROOFNG&ROOF JOISTS@REAR EXTDETERIORATD @ VARIOUS LOCATIONS.EXP 2/3CORNER HAD PART COLLAPSD ROOF APX20FT X 20FT LONG PRTLLY CLLPSD EXP3WALL,&EXP2WALL CRCKS.IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER #343297 (113023FEU20304PN)DATED NOVEMBER 30, 2023 #FEU20301PN | DOB VIOLATION - ACTIVE |
| Dec 6, 2023 | IMMEDIATE EMERGENCY PARTIAL DEMOLISH THE EXP 2/3 CORNER ROOF, EXP 2, AND EXP 3 WALLS AT TH E APPX 20FTX20FT PARTIALLY COLLAPSED ROOF, INSTALL SHORING @ 1ST STORY ROOF AT THE 50 FT W BY 195 FT D PORTION OF THE BLDG ADJ TO THE CONST SITE WHERE THE ROOF HAS INADEQUATE/COMPROMISED ROOF FRAMING.LATERALLY BRACE THE EXP 2 MAS #17993 | DOB VIOLATION - ACTIVE |
| Nov 30, 2023 | CONSTRUCTION VACATE/EMERGENCY WORK ORDER.ROOFNG&ROOF JOISTS@REAR EXTDETERIORATD@ VARIOUS LOCATIONS.EXP 2/3 CORNER HAD PART COLLAPSD ROOF APX20FT X 20FT W/20FT LONG PRTLLY CLLPSD EXP3WALL,&EXP2 WALL CRCKS.IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER #343297 (113023FEU20304PN)DATED NOVEMBER 30, 2023 #FEU20304PN | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Apr 22, 2026 | Structurally Compromised Buildings FTF-SC-INITL Report due for structurally compromised property | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 3) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)