3 floors · 142,888 sq ft · built 1950 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 142,888 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 184 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 184 days | Annual filing |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1987). Agency page | Dec 31, 2027 in 428 days | Next due 2027 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1159 days | Next cycle year 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-08 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 26, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT EXPOSURE 1, LEFT OF MAIN ENTRY, THERE IS A LARGE TREE THAT IS VERY DRIED OUT AND BRITTLE. BETWEEN EXIT #2 AND MAIN ENTRY, ADJACENT TO THE FLAG PO #35725212H | Apr 17, 2026 POP/IN-VIO | $0 |
| Feb 26, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: THE RETAINING WALL @ PROPERTY LINE OUTSIDE OF EXIT #7 IS LEANING AND SEPERATING. SEVERAL INCHES OUT OF PLUMB. REMEDY: REPAIR/REPLACE. #35725213J | Apr 17, 2026 POP/IN-VIO | $0 |
| Feb 26, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: THERE ARE SEVERAL EXTERIOR EXIT DOORS AND FRAMES, NOTABLY EXIT #2 AND OTHERS THAT ARE ROTTED AT BOTTOMS OF DOORS AND FRAME LEGS. FURTHER ROTTING AND #35725211X | Apr 17, 2026 POP/IN-VIO | $0 |
| Feb 26, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS AND EXIT DISCHARGES AND PUBLIC CORRIDORS AS PER BC 1006.1; 27-381. SEVERAL EMERGENCY LIGHTS WERE NOT OPERATIONAL WHEN TESTED. REMEDY #35725210Y | Apr 17, 2026 POP/IN-VIO | $0 |
| Feb 26, 2026 | Construction CLASS - 2 RE-ISSUE #35692170K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: IN ROOM #301, THE 2 GLAS PANELS AT THE FAR EFT CORNER FROM ENTRY ARE CRACKED. REMEDY: REPAIR/REPLACE. #35725209R | Apr 17, 2026 POP/IN-VIO | $0 |
| Feb 11, 2025 | Construction CLASS - 2 RE-ISSUE #35679089R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT T. O. I. OBSERVED THE GLASS IN ROOM #301 AT THE FAR LEFT CORNER IS CRACKED. 2 PANELS OF GLASS ARE CRACKED. ATTENTION NEEDED #35692170K | Apr 30, 2025 POP/IN-VIO | $0 |
| Sep 17, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NOTED: IN ROOM #301, THE WINDOW IN LEFT CORNER HAS CRACKED GLASS IN SEVERAL PANES OF THAT WINDOW. REMEDY: REPLACE/REPAIR THE CRACKED GLASS. #35679089R | Oct 23, 2024 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 29, 2026, 12:16 AM ET. BBL 5019870104.