Brooklyn · Block 2062 · Lot 19 · 11201

106 Fleet Place

30 floors · 99 apartments · 98,432 sq ft · built 2025 · class D7 · owner of record: 106 Fleet Realty Llc

0open violations
$26,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 98,432 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 852 days
Filing window not open yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1165 days
Next cycle year 2029
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2062). Agency page

Dec 31, 2032
in 2261 days
Next due 2032

Open violations

ECB / OATH (9) · $26,250 owed
IssuedViolationHearingBalance
Nov 13, 2025Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED CONSTRUCTION SUPERINTENDENT PERFORMING DUTIES OF FIRE SAFETY MANAGER. CONTRARY TO BC 3301.1.2 & FC 1408, A SEPARATE CERTIFIED FIRE SAFETY MANAGER IS REQUIRED WHERE A SITE SAFETY
#39546974X
Apr 8, 2027
$5,000
Nov 4, 2025Construction CLASS - 1
AT THE TIME OF MY INSPECTION,I OBSERVED CONCRETE POURING IN OPERATION ON THE 28 FLOOR, UPON REQUEST FOR THE CONCRETE SAFETY MANAGER TO VERIFY CODE COMPLIANCE OF 5 BUILDING AT THE LOCATION. DOB DOCUMENTS REVEAL
#39546658Y
Sep 22, 2026
IN VIOLATION
$2,500
Oct 13, 2025Unknown CLASS - 2
NEW 30 STORY BUILDING. OBSERVED SITE CLOSED UPON SEVERE WEATHER CONDITIONS INSPECTION OBSERVED 2 FORKLIFT ONE TOYOTA 10954611 AND OTHER WHITE COLOR NO SERIE ON IT INADEQUATE STORED ON ROAD WAY .& PARKED ON UN
#39545938Y
Feb 4, 2027
$2,500
Oct 13, 2025Construction CLASS - 1
NEW 30 STORY BUILDING . UPON SEVERE WEATHER CONDITION SITE CLOSED NO ONGOING CONSTRUCTION ACTIVITY AND NOTED ON CORNER EXPOSURE 1,2 DEBRIS NETTING RIPPED AT LEVEL FLORS 25 AND UP ALSO AT LEVEL OF SWS CONTRARY
#39545937M
Feb 4, 2027
$5,000
Oct 13, 2025Unknown CLASS - 2
NEW 30 STORY BUILDING . UPON INSPECTION ON SEVERE WEATHER CONDITIONS WHERE AN INDIVIDUAL BUILDING BEING CONSTRUCTED OR DEMOLISHED HAS A FOOTPRINT OF BETWEEN 5,000 AND 40,000 SQUARE FEET, A COMPETENT WATCHPERSO
#39545943Z
Feb 4, 2027
$2,500
Sep 27, 2025Construction CLASS - 2
OBSERVED JERSEY BARRIERS OCCUPYING ROADWAY AT EXP#1 NOT AS PER MANUFACTURES SPECIFICATION. JERSEY BARRIERS SEVERAL NOT INTERLOCKED AND NOT FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLOWING UNINTE
#39545401Y
Mar 4, 2027
$1,250
Sep 27, 2025Unknown CLASS - 2
BC3303.3 WATCHPERSON. 30 STORY NEW BUILDING, BUILDING APPROXIMATELY 5573 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALERT WATCH
#39545400M
Mar 4, 2027
$2,500
Sep 5, 2025Unknown CLASS - 2
BC3303.15 CONCRETE WASHOUT WATER: DURING INSPECTION OF PROPOSED 30 STORY BUILDING AT 20 STORIES, UNDER GOING CONCRETE POURING, I OBSERVED CONCRETE WATER FLOWING INTO THE SEWER SYSTEM. THERE WAS NO MESH, HAY OR
#39544500P
Mar 15, 2027
$2,500
Sep 5, 2025Construction CLASS - 1
INSPECTION OF A 30 STORY BUILDING AT THE 20TH STORY, I OBSERVED THAT THERE WERE NO DOORS ENCLOSING THE STAIRWAYS. AS PER THE FDNY WAIVER AGREEMENT STAIRWAYS WILL BE ENCLOSED WITH HUNG DOORS AS PER BC3303.11 THE
#39544499R
Mar 15, 2027
$2,500
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 5:20 AM ET. BBL 3020620019.

Look up another building