Queens · Block 10129 · Lot 40 · 11433

106-57 Union Hall Street

2 floors · 2 apartments · 1,710 sq ft · built 1915 · class B2 · owner of record: Bhutta, Khalid Mehmood

48open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
290dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 290 days
Registered through 2027-09-01

Open violations

ECB / OATH (5)
IssuedViolationHearingBalance
Aug 25, 2010Construction CLASS - 2
WORK W/O A PERMIT: EXPIRED PERMIT. PERMIT #410237934-EW-OT ISSUED ON 3.24.09, EXPIRED 11.12.009. REMEDY: RENEW PERMIT.
#34859988M
Oct 19, 2010
WRITTEN OFF
$0
Aug 25, 2010Construction CLASS - 1
WORK W/O A PERMIT. NOTED: NEW ELECTRIC WIRING THROUGHOUT 1ST FLR & CELLAR INCLUDING 2 NEW SERVICE PANELS IN CELLAR. WORK APPEARS APPROX 70% COMPLETE.FULL STOP WORK ORDER ISSUED - PURSUANT TO 28-207.2 AND POSTED
#34859989Y
Oct 19, 2010
WRITTEN OFF
$0
Aug 25, 2010Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. NOTED: AT 2ND FLR APT CRACKED WALL IN VARIOUS LOCATIONS THROUGHOUT AND ROTTED FLRG W/A HOLE APPROX 1'X1 1/2' AT REAR BEDROOM. AT REAR YARD APPROX 7 CU YDS OF
#34859990L
Oct 19, 2010
WRITTEN OFF
$0
Aug 20, 2010Construction CLASS - 2
FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DEFECT NOTED: AT EXTERIOR FRONT MASONRY WELL HOLE & STAIR FROM GRADE TO CELLAR MISSING GUARDHAND/GUARD RAILS. REMEDY: MAKE SITE SAFE-REPAIR/REPLACE
#34849505J
Oct 12, 2010
WRITTEN OFF
$0
Dec 30, 2008Construction CLASS - 3
FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCES. ALT II JOB #401983485.NOTE: ACCESS STAIRS LEADING TO CELLAR FROM FRONT OF BLDG NO FITTED OR HAS NO SECURITY GUARD AND HAND RAILINGS INSTALLED AS A SAFETY PRECAUTI
#34751476Y
Feb 24, 2009
WRITTEN OFF
$0
DOB (3)
IssuedViolationStatus
Dec 2, 2010FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#02083
DOB VIOLATION - ACTIVE
Aug 25, 2010CONSTRUCTION
WORK W/OUT PERMIT
#AHEC01
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Aug 25, 2010CONSTRUCTION
WORK W/OUT PERMIT
#AHEC02
VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Dec 2, 2010AEUHAZ FTC-AEU-HAZ
Active
HPD (39) · C 3 · B 29 · A 7
IssuedClassViolationCorrect by
Sep 8, 2010A§ 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 2nd STORYDec 12, 2010
Sep 8, 2010BApt 2FL · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORYOct 13, 2010
Sep 8, 2010BApt 2FL · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORYOct 13, 2010
Sep 8, 2010CApt 2FL · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2FL, 2nd STORYSep 14, 2010
Sep 8, 2010B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED CEILING AT PUBLIC HALL, 2nd STORYOct 13, 2010
Sep 8, 2010B§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING BALUSTER AT BANISTER AT STAIR AT PUBLIC HALL, 1st STORYOct 13, 2010
Sep 8, 2010B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED WALLS AND CEILING AT VESTIBULE AT PUBLIC HALL, 1st STORYOct 13, 2010
Sep 8, 2010A§ 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING AT VESTIBULE AT PUBLIC HALL, 1st STORYDec 12, 2010
Sep 8, 2010B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL SIDING AT EXTERIOR WALL AT BUILDING FRONT YARDOct 13, 2010
Sep 8, 2010BApt 2FL · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORYOct 13, 2010
Jul 23, 2009BApt 2 · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORYAug 27, 2009
Jul 23, 2009B§ 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE EAST & WEST YARDAug 27, 2009
Jul 23, 2009BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER IN THE 4th ROOM FROM EAST LOCATED AT APT 2Aug 27, 2009
Jul 23, 2009BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER IN THE KITCHEN LOCATED AT APT 2Aug 27, 2009
Jul 23, 2009BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER IN THE PRIVATE HALLWAY LOCATED AT APT 2Aug 27, 2009
Jul 23, 2009BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING & WALLS IN THE BATHROOM LOCATED AT APT 2Aug 27, 2009
Jul 23, 2009B§ 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE HOLD ITEM 1ST & 2ND STORY AT PUBLIC HALLAug 27, 2009
Aug 13, 2008A§ 27-2049 ADM CODE - POST AND MAINTAIN A STREET NUMBER ON THE FRONT OF THE DWELLING PLAINLY VISIBLE FROM THE SIDEWALKNov 16, 2008
Aug 13, 2008A§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING DOOR BELL AT ENTRANCE TO BLDG.Nov 16, 2008
Aug 13, 2008A§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE EXTERIOR SIDING FRONT WALL.Nov 16, 2008
Aug 13, 2008A§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASH CELLAR FRONT.Nov 16, 2008
Jun 6, 2007BApt 2 · § 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION LOCKNUT AT WASTE LINE OF WASHBASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 24, 2007
Jun 6, 2007BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 24, 2007
Jun 6, 2007C§ 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION HOT WATER SUPPLY PIPE AT BATHTUB FAUCET 1ST STORY APARTMENT # 1, BATHROOM.Jun 25, 2007
Jun 6, 2007C§ 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN SINK AT KITCHEN 1ST STORY APARTMENT # 1.Jun 25, 2007
Jun 6, 2007B§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN AND BATHROOM 1ST STORY APARTMENT # 1.Jul 24, 2007
Jun 6, 2007B§ 27-2026 ADMIN. CODE: REPAIR BY CLOSING SO AS TO BE GAS TIGHT ALL OPENINGS IN THE WASTE LINE AT KITCHEN SINK 1ST STORY APARTMENT # 1.Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LOCKING DEVICE ON EXIT DOOR TO REAR YARD AT KITCHEN 1ST STY APARTMENT # 1.Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN AND VINYL FLOORING AT KITCHEN 1ST STORY APARTMENT # 1.Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE GAS STOVE 1ST STORY APARTMENT # 1, KITCHEN.Jul 24, 2007
Jun 6, 2007B§ 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASH BASIN 1ST STORY APARTMENT # 1, BATHROOM.Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE AND VINYL FLOOR AT BATHROOM 1ST STORY APARTMENT.Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING ALL ROOMS 1ST STORY APARTMENT # 1.Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANEL UPPER SOUTH WINDOW SASH 1ST STORY APARTMENT #1, WEST ROOM.Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANEL LOWER NORTH WINDOW SASH 1ST STORY APARTMENT # 1, WEST ROOMJul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ENTRANCE DOOR TO 1ST STORY APARTMENT # 1 .Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED WIRE CEILING 1ST STORY PUBLIC HALL.Jul 24, 2007
Jun 6, 2007B§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURE CEILING 1ST STORY PUBLIC HALL.Jul 24, 2007
Jun 6, 2007AApt 2 · § 27-2026 ADMIN. CODE: RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL AT IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTSep 22, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 11:23 AM ET. BBL 4101290040.