Bronx · Block 2705 · Lot 9 · 10459

1046 Intervale Avenue

1 floors · 20,000 sq ft · built 1971 · class W9 · owner of record: Nyc Department Of Education

7open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1166dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1166 days
Next cycle year 2029

Open violations

ECB / OATH (6)
IssuedViolationHearingBalance
Jul 19, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3;27-345. NOTED: THE HOT WATER HEATER ROOM BY THE MAIN ENTRANCE HAS CRACKS, MISSING MASONRY AND HOLES IN THE CMU BLOCK WALL. RE
#35676348Z
Oct 20, 2023
POP/IN-VIO
$0
Jul 19, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: THE HOT WATER HEATER ROOM BY THE MAIN ENTRANCE HAS STORAGE OF BOXES, PLASTIC CONTAINERS, BAGS, SUPPLIES, AND MISCELLANEOUS ITEMS IN VARIOUS AREAS TH
#35676347R
Oct 20, 2023
POP/IN-VIO
$0
Jun 8, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BLG IN CODE COMPLIANT MANNER ILLUMINATION FOR EXITS, EXITS DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381 IN ENTRANCE ROOM ONE PLACE TWO LIGHTS ARE NOT ILLUMINATED AND ROOM O.5 ONE PL
#35335587K
Aug 17, 2018
POP/IN-VIO
$0
Apr 9, 2018Construction CLASS - 2
FAILURE TO COMPLY W COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION# 35270609H ISSUED ON 6/19/2017 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01(D)(2). AN ACCEPTIBLE CERTIFICATE HAS NOT YET BEEN FI
#37009729X
Jun 29, 2018
POP/IN-VIO
$0
Jun 19, 2017Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR BLDG DEPARTMENT RECORDS-OBSERVED BOILER RM CONVERTED TO STORAGE RM.REM DISCONTINUE ILLEGAL USE OR AROUND THE C OF O
#35270609H
Sep 15, 2017
STIPULATION/IN-VIO
$0
Nov 4, 2016Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. LACK OF EMERGENCY LIGHTING FOR EXITS, EXITS DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-542. NOTED: BROKEN OF DEFECTIVE EMERGENCY LIGHTING AT 1ST FLOOR
#35216696H
Jan 20, 2017
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 2)
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 6:30 PM ET. BBL 2027050009.