2 floors · 185,888 sq ft · built 1972 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 43 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 185,888 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3021). Agency page | Dec 31, 2031 in 1869 days | Next due 2031 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-30 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 11, 2026 | Construction CLASS - 2 REISSUE #35721388N. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER NC 1006.1; 27-381. NOTED: ALL EMERGENCY LIGHT FROM 3RD FLOOR DOWN TO T #35732813Z | Jun 26, 2026 POP/IN-VIO | $0 |
| May 11, 2026 | Construction CLASS - 2 RE-ISSUE #35721392X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OUTSIDE IN FRONT OF EXIT "10" HANDRAIL ALONG SIDE RAMP ISMISSING TOP RAIL. REMEDY: REPAIR AND/OR REPLACE. #35732815M | Jun 26, 2026 POP/IN-VIO | $0 |
| May 11, 2026 | Construction CLASS - 2 RE-ISSUE #35721386J. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: INTERIOR FPSC DOORS DO NOT SELF-CLOSE PROPERLY AT CLASSROOM #S-243. 1ST FLOOR RM #S-103, 11, 145. REMEDY: REPAIR AND/OR REPLACE #35732814K | Jun 26, 2026 POP/IN-VIO | $0 |
| May 11, 2026 | Construction CLASS - 2 RE-ISSUE #35721389P. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRE-STOPPING PER BC 712.3; 27-345. NOTED: IN ELECTRIC METER ROOM, A SECTION OF CMU BLOCK WAS REMOVED TO RUN PIPES THRU IT AND NO F #35732812R | Jun 26, 2026 POP/IN-VIO | $0 |
| Aug 8, 2025 | Construction CLASS - 1 REISSUE #35684936P. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED ALL EMERGENCY LIGHTS WITH BATTERY BACK-UP POW #35721388N | Sep 5, 2025 POP/IN-VIO | $0 |
| Aug 8, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED INTERIOR FPSC DOORS NOT CLOSING PROPERLY AT: 3RD FL STAIR F AND SMOKE DOOR BY RM 301. 2ND FL STAIR G, 1ST FL STAIR C AND G, SMOKE DOORS AT EXIT #4, 7 #35721386J | Sep 5, 2025 POP/IN-VIO | $0 |
| Aug 8, 2025 | Construction CLASS - 2 REISSUE #35684934L. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED EXIT #10 RAILING ALONG SIDE RAMP, WAS MISSING TOP RAIL/HANDRAIL. #35721392X | Sep 5, 2025 POP/IN-VIO | $0 |
| Aug 8, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC712.3; 27-345. AT CELLAR LEVEL ELECTRIC METER ROOM, AN APPROX 2FT PENETRATION IN CMU WALL FOR CONDUIT. NO FIRESTOPPING PROVIDED. REM #35721389P | Sep 5, 2025 POP/IN-VIO | $0 |
| Sep 30, 2024 | Construction CLASS - 2 REISSUE#35677125X DATE OF ISSUE:07.13.2023 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION NOTED AND OBSERVED HANDRAIL AT EXIT 10 TOP RAIL MISSING.REM:REPAIR OR INSTALL HANDRAIL #35684934L | Dec 6, 2024 POP/IN-VIO | $0 |
| Sep 30, 2024 | Construction CLASS - 2 REISSUE#35663473P DATE OF ISSUE:07.13.2023 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.AT THE TIME OF INSPECTION I OBSE #35684936P | Dec 6, 2024 POP/IN-VIO | $0 |
| Jul 13, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT 3FL. 303, SMOKE STAIR E & F, CORRIDOR BY 301, 1FL. SMOKE EXIT 8, STAIR CG, EXIT 7, 4 AND MAIN ENTRANCE DOOR ARE NOT CLOSING PROPERLY RUBBING. REME #35663474R | Nov 3, 2023 POP/IN-VIO | $0 |
| Jul 13, 2023 | Construction CLASS - 2 REISSUE #35657854H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER; ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381. NOTED OBSERVED EMERGENCY LIGHTS W/ BATTERY BACKUP THR #35663473P | Nov 3, 2023 POP/IN-VIO | $0 |
| Jul 13, 2023 | Construction CLASS - 2 REISSUE#35657852Y FAILURE TO MAINTAIN BUILDING IN CODE COMPLPIANT MANNER, NOTED HARDRAIL AT EXIT 10 TOP RAIL MISSING, BULKHEAD AT STAIR 8 CEILING SPALLING, 2FL. STAIR H SPALLING CEILING,AT EXIT 7 METAL SADDLE T #35677125X | Nov 3, 2023 POP/IN-VIO | $0 |
| May 25, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER:ILLUMINATION FOR EXITS,EXIT DISCHARGES&PUBLIC CORRIDORS PER BC1006.1;27-381.NOTED:OBSERVED EXISTING EMERGENCY LIGHTS W/BATTERY BACKUP POWER THRUOUT ENTIRE SCHOOL #35657854H | Sep 16, 2022 POP/IN-VIO | $0 |
| May 25, 2022 | Construction CLASS - 2 REISSUED35577359K FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER:NOTED:OBSERVED RAILING OUTSIDE OF EXIT10 IN DISREPAIR,DETACHED FROM FOOTING,MISSING TOP&SIDE RAILS.REPAIR &OR REPLACE #35657852Y | Sep 16, 2022 POP/IN-VIO | $0 |
| Dec 1, 2021 | Elevators CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE 2014 BUILDING CODES. REMEDY/ INSTALL DLM , FILE AND PERFORM TEST WITH NYC DOB #39052066K | Dec 13, 2021 POP/IN-VIO | $0 |
| May 27, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: OBSERVED JUSTOUTSIDE EXIT 10 AT CAFETERIA. THE HANDRAIL/GUARDRAIL AT RAMP IS DAMAGE& LOOSE DUE TO A DELIVERY TRUCK HITTING THE GUARDRAIL. REMEDY: REPAIR #35577359K | Oct 29, 2021 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #07721 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #07722 | DOB VIOLATION - ACTIVE |
| Jun 9, 1994 | LOCAL LAW 62/91 - BOILERS #01992 | DOB VIOLATION - ACTIVE |
| Jun 9, 1994 | LOCAL LAW 62/91 - BOILERS #01993 | DOB VIOLATION - ACTIVE |
| Jun 9, 1994 | LOCAL LAW 62/91 - BOILERS #01994 | DOB VIOLATION - ACTIVE |
| Jun 9, 1994 | LOCAL LAW 62/91 - BOILERS #01992 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |