ECB / OATH (11) · $51,310 owed
IssuedViolationHearingBalance
Sep 8, 2026Construction CLASS - 2
AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED WORKERS STANDING ON TOP OF TOOLBOX AND ON BATHTUB DOING ELECTRICAL WORK FRAMING AND NOT ON LADDERS. FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES
#39558905K
Nov 18, 2026
$5,000
Sep 8, 2026Unknown CLASS - 1
BC 3307.4.7 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED BOOM TRUCK AND LARGE GENERATOR ON STREET ADJACENT TO SIDEWALK SHED WITH NO 4 FEET SOLID BARRIER FROM GROUND LEVEL AND NO 18 GAUGE W
#39558906M
Nov 18, 2026
$5,000
Sep 8, 2026Unknown CLASS - 1
BC 3307.2.1 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED LARGE GENERATOR ON STREET ADJACENT TO SIDEWALK SHED, UPON REQUEST FOR DOT PERMIT NONE WAS PROVIDE OR AT JOBSITE, FAILURE TO PROVIDE
#39558907Y
Nov 18, 2026
$5,000
Aug 25, 2026Unknown CLASS - 1
AT THE TIME OF MY INSPECTION, I OBSERVED CONCRETE PUMP TRUCK, CONCRETE WASHOUT BOX, GARBAGE TRUCK AT EXPOSURE #1,2. ADJACENT TO SIDEWALK SHED, THERE WERE NO 4 FEET SOLID PLYWOOD BARRIERS FROM GROUND LEVEL WITH
#39558380R
Nov 4, 2026
$5,000
Jul 29, 2026Unknown CLASS - 1
BC 3301.13.6: AT THE TIME OF INSPECTION OF A 6-STORY, 21-UNIT BUILDING, DOB RECORDS SHOWED SUPERINTENDENT RAFAEL FERNANDEZ (LIC. #029162) WAS DESIGNATED UNDER PERMIT B00968657-I1-GC, & WAS DESIGNATED ON ACTIVE
#39557248P
May 4, 2027
$5,000
Jul 29, 2026Unknown CLASS - 1
AT TIME OF INSPECTION OF AN ACTIVE JOB SITE FOR A NEW 6 STORY BUILDING, OBSERVED WORK IN PROGRESS AT THE 3RD FLOOR DECK WITH NO PROTECTION PROVIDED FOR THE ADJOINING PROPERTY AT EXPOSURE #3, CONTRARY TO CODE RE
#39557211L
Oct 7, 2026
DEFAULT
$10,030
Jul 29, 2026Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED EQUIPMENT AND CONSTRUCTION MATERIALS STORED IN THE PUBLIC ROADWAY ADJACENT TO THE JOB SITE. MATERIALS/EQUIPMENT WERE PILED OVER 3 FEET HIGH WITHOUT THE REQUIRED SOLID FENCE OR B
#39557212N
Oct 7, 2026
DEFAULT
$5,030
Apr 28, 2026Construction CLASS - 2
PROPOSED 6 STORY BUILDING. CONSTRUCTION SITE AT EXCAVATION/FOUNDATION PHASE, OBSERVED ERECTED FENCE WITH MISSING FENCE PANELS AT EXP#3 CONTRARY TO FENCE DRAWINGS ON CRM AND USING ADJACENT PROPERTY FENCE AS A CO
#39553573K
Jan 14, 2027
PENDING
$1,250
Apr 28, 2026Unknown CLASS - 1
CONSTRUCTION SUPERINTENDENT #027395 IS DESIGNATED ON THE PW2 FOR MAJOR BUILDING UNDER PERMIT #M00951254-I1, AND SIMULTANEOUSLY ON ACTIVE LOW-RISE JOB SITES UNDER THE PERMITS B001139256-I1-FD AND B01204725. STOP
#39553572Z
Jan 14, 2027
$5,000
Apr 20, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING AT EXCAVATION/FOUNDATION PHASE, UPON REVIEW OF THE FOUNDATION/EXCAVATION PLANS IT HAS ONLY 2 REBAR BEAMS IN THE FOUNDATION FROM EXPOSURE #2 BUT SITE CONDIT
#39553210L
Dec 1, 2026
$2,500
Mar 19, 2026Construction CLASS - 1
OBSERVATION: WORK IN PROGRESS(EXCAVATION, DRIVING PILES). WALKED SITE WITH COMPETENT PERSON. DOCUMENTS PROVIDED. VIOLATING CONDITION OBSERVED EARHWORK IN PROGRESS W/O NOTIFICATION. VIO FOR FAILURE TO NOTIFY DEP
#39552054Y
Dec 17, 2026
$2,500
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 8, 2026ECBConstruction: AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED WORKERS STANDING ON TOP OF TOOLBOX AND ON BATHTUB DOING ELECTRICAL WORK FRAMING AND NOT ON LADDERS. FAILURE TO PROVIDE ADEQUATE SAFETY MEASURESClosed
Sep 8, 2026ECBUnknown: BC 3307.4.7 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED BOOM TRUCK AND LARGE GENERATOR ON STREET ADJACENT TO SIDEWALK SHED WITH NO 4 FEET SOLID BARRIER FROM GROUND LEVEL AND NO 18 GAUGE WClosed
Sep 8, 2026ECBUnknown: BC 3307.2.1 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED LARGE GENERATOR ON STREET ADJACENT TO SIDEWALK SHED, UPON REQUEST FOR DOT PERMIT NONE WAS PROVIDE OR AT JOBSITE, FAILURE TO PROVIDEClosed
Aug 25, 2026ECBUnknown: AT THE TIME OF MY INSPECTION, I OBSERVED CONCRETE PUMP TRUCK, CONCRETE WASHOUT BOX, GARBAGE TRUCK AT EXPOSURE #1,2. ADJACENT TO SIDEWALK SHED, THERE WERE NO 4 FEET SOLID PLYWOOD BARRIERS FROM GROUND LEVEL WITHClosed
Aug 25, 2026ECBConstruction: AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED CONSTRUCTION FENCE IN PLACE AT EXPOSURE #1 AND 2, UPON REVIEW OF DOB RECORD IT REVEAL THAT THE CONSTRUCTION FENCE PERMIT HAS BEING EXPIRED FROMClosed
Jul 29, 2026ECBUnknown: BC 3301.13.6: AT THE TIME OF INSPECTION OF A 6-STORY, 21-UNIT BUILDING, DOB RECORDS SHOWED SUPERINTENDENT RAFAEL FERNANDEZ (LIC. #029162) WAS DESIGNATED UNDER PERMIT B00968657-I1-GC, & WAS DESIGNATED ON ACTIVEClosed
Jul 29, 2026ECBUnknown: AT TIME OF INSPECTION OF AN ACTIVE JOB SITE FOR A NEW 6 STORY BUILDING, OBSERVED WORK IN PROGRESS AT THE 3RD FLOOR DECK WITH NO PROTECTION PROVIDED FOR THE ADJOINING PROPERTY AT EXPOSURE #3, CONTRARY TO CODE REClosed
Jul 29, 2026ECBUnknown: AT TIME OF INSPECTION, OBSERVED EQUIPMENT AND CONSTRUCTION MATERIALS STORED IN THE PUBLIC ROADWAY ADJACENT TO THE JOB SITE. MATERIALS/EQUIPMENT WERE PILED OVER 3 FEET HIGH WITHOUT THE REQUIRED SOLID FENCE OR BClosed

Check the agency records