Bronx · Block 3015 · Lot 49 · 10460

1029 East 173 Street

1 floors · 15,500 sq ft · built 1929 · class G1 · owner of record: Nyc Department Of Sanitation

22open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
44dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-12-14 (Accepted). Agency page

Dec 31, 2026
in 44 days
1 of 1 without an accepted 2026 report yet
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 775 days
Next cycle year 2028

Open violations

ECB / OATH (4)
IssuedViolationHearingBalance
May 22, 2019Unknown CLASS - 1
TEMPORARY POWER INSTALLED WITHOUT A PERMIT., OBTAIN PERMIT
#39003286L
May 29, 2019
POP/IN-VIO
$0
May 22, 2019Construction CLASS - 1
TEMPORARY FUEL STORAGE TANK INSTALLED WITHOUT A PERMIT., OBTAIN PERMIT
#39003269J
May 29, 2019
POP/IN-VIO
$0
Jun 18, 2018Boilers CLASS - 2
36)AS PER DOB RECORDS, BOILER IS NOT REGISTERED WITH THIS DEPT.
#32096972M
Oct 19, 2018
POP/IN-VIO
$0
Jun 18, 2018Construction CLASS - 1
B101,50. 50-FOUND NO PERMITS TO INSTALL BOILER AT SITE AS PER DOB RECORDS. BURNHAM MODEL #V910A BTU 1578 MBH.
#32096971K
Nov 2, 2018
POP/IN-VIO
$0
DOB (11)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06346
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
#25243
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#05467
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#05436
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#26929
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#09863
DOB VIOLATION - ACTIVE
Sep 23, 2021CONSTRUCTION
EMERGENCY WORK ORDER-MASONRY WALLS AND WOOD FRAMED ROOF DETACHED VACANT BLDG IN SEVERE STATE OF DISREPAIR. ONE BOWSTRING TRUSS COLLAPSE ON 6/19. THE ROOF HAS FURTHER COLLASPED. THE REMAINDER OF THE ROOF FRAMING(BOWSTRING TRUSSES)IS IN STATE OF DISREPAIR AND THERE IS POTEN OF FURTHER COLLASPE. REMEDY
#FEU20301XC
DOB VIOLATION - ACTIVE
Jun 24, 2020CONSTRUCTION
FAILURE TO COMPLY W/COMM'S ORDER#315795 07/01/19 TO FILE FOR PERMIT BY 08/01/2019 AND START WORK BY 09/01/2019-MAKE BLDG CODE COMPLIANT AS OF 06/24/2020.BLDG HAS NOT BEEN REPAIRED OR DEMOLISHED.NO JOBS FILED FOR PERMIT WITH THE DEPARTMENT.IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDR # 315795
#FEU20301XC
DOB VIOLATION - ACTIVE
Jul 29, 2019CONSTRUCTION
EMERGENCY WORK ORDER:1 STRY DETACH MASN WALLS&WOOD TRUSS FRAMED ROOF (BOW STRING TRUSSES)ON 6/28/19 ONE TRUSS OF ROOF COLLAP.THE ROOF PART COLLAP APPX 50'WIDE SECTION.THE EXT WALLS ARE NOT BRACED AND THERE IS POSSIBILITY OF COLLAP.IMMED BRACE WALL ALONG WEST FARM ROAD UND DIRECT AND CONTINOUS SUPERV
#FEU20301XC
DOB VIOLATION - ACTIVE
Jul 1, 2019CONSTRUCTION
FTM:TRUSS ROOF,APPROX 150'W BY 110'D IN DISREP.ONE ROOF TRUSS COLLAP CAUSING A 50' WIDE SECT OF ROOF TO PART COLLAP&HANG FROM OTHERTRUSSES FRNT WALL IS PART UNBRACED.DETERIOR&CRACKED BRICKS NOTED ON ALL WALLS FULLY VACATE BLDG. OWNER ENGAGE PE EVALUATE STRUCTURE&MAKE BLDG CODE OMPLIANT UNDER PRMT. F
#FEU20301XC
DOB VIOLATION - ACTIVE
Jun 28, 2019CONSTRUCTION
EMERG WRK ORDER: ONE ROOF TRUSS COLLAP BY EXP4 & REMAINDER OF TRUSS IS RESTING ON EXP3 WALL.ROOF SUPPORTED ON THIS TRUSS HAS PART COLLAP AREA (50'WX100'D +/-),LEAVING PERIMETER WALLS IMPROPERLY BRACED. OWNR IMMED ENGAGE PE&ENDORSED CONTR ERECT T/B/F ALONG WEST FARM ROAD TO PROTECT THE PUBLIC.WRK DON
#FEU20301XC
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 8:17 PM ET. BBL 2030150049.