5 floors · 31,800 sq ft · built 2017 · class H9 · owner of record: Superior Beach 21st Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 31,800 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 21, 2026 | Unknown CLASS - 2 MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED ON THE ROOF THE HOT WATER TANK ROOM HAS NO EMERGENCY REMOTE SHUT OFF AT THE POINT OF EGRESS. MUST PROVIDE REMOTE SHUT OFF IN EMERGENC #39196989L | Nov 17, 2026 | $800 |
| Jul 21, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ATOI OBSERVED OBSTRUCTED SPRINKLER HEADS THROUGH OUT BUILDING CONTRARY TO FGC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES #39196977Y | May 18, 2027 | $2,500 |
| Jul 21, 2026 | Construction CLASS - 1 ATOI OBSERVED NON FIRE RATED PVC BEING USED ON THE HOT WATER HEATER INTAKES IN THE ROOF MECHANICAL ROOM WHICH IS CONTRARY TO FGC 503.4.1, REPAIR AND/REPLACE #39196978X | Nov 17, 2026 ADMIT/IN-VIO | $0 |
| Jul 1, 2026 | Elevators CLASS - 2 CLASS 2: ELEVATOR COUNTERWEIGHTS PRODUCE EXCESSIVE NOISE. FOUND ONE TOP ROLLER GUIDE ON THE COUNTERWEIGHT RAIL IS WORN OUT, CAUSING METAL-ON-METAL CONTACT AND EXCESSIVE RUNNING NOISE. REMEDY (AS PER ASME A17.1/ #39194428M | Nov 17, 2026 | $625 |
| Jul 1, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATION AT BASEMENT LEVEL., REPAIR AND/OR REPLACE #39194542X | Nov 17, 2026 | $1,250 |
| Jul 1, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOOR ON ROOF LEVEL. (BOILER ROOM)POTENTIAL HAZARD, REPAIR/REPLACE DOOR #39194543H | Nov 17, 2026 | $625 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
| Aug 31, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 21, 2026 | ECB | Unknown: MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED ON THE ROOF THE HOT WATER TANK ROOM HAS NO EMERGENCY REMOTE SHUT OFF AT THE POINT OF EGRESS. MUST PROVIDE REMOTE SHUT OFF IN EMERGENC | Closed |
| Jul 21, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ATOI OBSERVED OBSTRUCTED SPRINKLER HEADS THROUGH OUT BUILDING CONTRARY TO FGC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES | Closed |
| Jul 21, 2026 | ECB | Construction: ATOI OBSERVED NON FIRE RATED PVC BEING USED ON THE HOT WATER HEATER INTAKES IN THE ROOF MECHANICAL ROOM WHICH IS CONTRARY TO FGC 503.4.1, REPAIR AND/REPLACE | Open |