Manhattan · Block 883 · Lot 21 · 10016

102 Lexington Avenue

4 floors · 7 apartments · 4,188 sq ft · built 1910 · class C7 · owner of record: Lexington 100 Properties Llc

11open violations
$14,980ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029

Open violations

ECB / OATH (4) · $14,980 owed
IssuedViolationHearingBalance
Sep 4, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OF 4 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH PERMIT # M01223537 EXPIRED 9-1-26 CAUSING HAZARDOUS CONDITIONS.RENEW
#39558820L
Jan 7, 2027
PENDING
$1,250
Jul 22, 2026Construction CLASS - 2
FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39147836J ISSUED ON 05-13-2025 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER., FILE A CERTIFICATE OF CORRECTION
#39197156L
Oct 1, 2026
DEFAULT
$1,280
Sep 29, 2025Construction CLASS - 2
FAILURE TO MAINTAIN ELECTRIC CONNECTION AS PER CODE 3307.6.4.8 LIGHTING, OBSERVED LAMP CONNECTION ACCESSORY AND FIXTURE INCLUDED WIRING DIDN'T CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY ELECTRICAL CODE. F
#39545443M
Dec 4, 2025
DEFAULT
$10,000
May 13, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT THE TIME OF INSPECTION OBSERVED AT EXPOSURE 1 OF THE FACADE DETERIORATED LINTELS AT TOP FLOOR WINDOWS, STEP CRACKS AND MISSING MORTAR JOINTS AT M
#39147836J
Sep 4, 2025
IN VIOLATION
$2,450
DOB (2)
IssuedViolationStatus
May 14, 2025IMMEDIATE EMERGENCY
REMEDY: PROVIDE APPROXIMATELY 20 LINEAR FEET OF SIDEWALK SHED AR EXPOSURE 1 TO SAFEGUARD THE PUBLIC.AND PROPERTY
#19227
DOB VIOLATION - ACTIVE
May 13, 2025CONSTRUCTION
REQUESTING ENGINEERING REPORT DUE TO BUILDING FA ADE IN A STATE OF DISREPAIR. OBSERVED AT EXPOSURE 1 DETERIORATED LINTELS AT TOP FLOOR WINDOWS, STEP CRACKS AND MISSING MORTAR JOINTS.
#25-00817
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (4) · C 0 · B 3 · A 1
IssuedClassViolationCorrect by
Jun 12, 2024AApt 4R · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE GROUT AT THE CERAMIC WALL TILES OF SOUTH WALL, EAST WALL, AND WEST WALL IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 15, 2024
Jun 12, 2024BApt 4R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING APPROX 4 SQ FT, SOUTH WALL APPROX 4 SQ FT, AND AT THE WEST WALL APPROX 3 SQ FT IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 17, 2024
Jun 12, 2024BApt 4R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING APPROX 10 SQ FT, AT THE SOUTH WALL APPROX 5 SQ FT, AT THE WEST WALL APPROX 1 SQ FT, AND AT THE EAST WALL APPROX 4 SQ FT IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 17, 2024
Aug 30, 2021BApt 4R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTOct 4, 2021

Issued in the last 120 days

DateSourceWhatNow
Sep 4, 2026ECBUnknown: AT TIME OF INSPECTION OF 4 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH PERMIT # M01223537 EXPIRED 9-1-26 CAUSING HAZARDOUS CONDITIONS.RENEWOpen
Jul 22, 2026ECBConstruction: FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39147836J ISSUED ON 05-13-2025 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER., FILE A CERTIFICATE OF CORRECTIONOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 5:13 PM ET. BBL 1008830021.

Look up another building