Queens · Block 1641 · Lot 1 · 11369

102-05 Ditmas Boulevard

10 floors · 251,467 sq ft · built 1981 · class H3 · owner of record: Asap Ditmars Llc

7open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
66dto Annual boiler inspection (7 boilers)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (7 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-03-11 (Accepted). Agency page

Dec 31, 2026
in 66 days
7 of 7 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 251,467 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $90,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 849 days
Filing window not open yet
Energy audit and retro-commissioning (2031) Likely applies
Local Law 87 · Calendar year 2031
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1641). Agency page

Dec 31, 2031
in 1892 days
Next due 2031

Open violations

ECB / OATH (0)

None open.

DOB (4)
IssuedViolationStatus
Nov 25, 2024HAZARDOUS CONDITION (FACADE)
CYCLE 9C UNSAFE REPORT FILED
#911952
DOB VIOLATION - ACTIVE
Jun 11, 2024CONSTRUCTION
FAILURE TO MAINTAIN FACADE AND APPURTENANCES.OBSERVED LAMINATING,SPALL ING STUCCO AT EXP2 SOUTH ELEV.REMEDY:OWNER TO IMMEDIATELY RETAIN A NYC REG DESIGN PROFESSIONAL WITH QEWI CERTIFICATION AND EXPERIENCE IN STUC CO TO INSPECT AND EVALUATE 100% OF THE STUCCO FACADE AND ALL DECORATIV E STONES ON ALL
#FA0301AB
DOB VIOLATION - ACTIVE
Jun 11, 2024CONSTRUCTION
EMERGENCY WORK ORDER DUE TO DELAMINATING STUCCO AT EXP2 SOUTH ELEV AT THE PARAPET LEVEL.REMEDY:OWNER IS TO IMMEDIATELY PROVIDE A PLOT PLAN W ITH DIMENSION NOTING THE AREA TO BE CLOSED OFF,NO WORKS SHOULD BE NEAR THE DEFECTED FACADE.RETAIN A NYS REG PROFESSIONAL TO DIRECT AND SUPERV ISE ALL WORKS AND
#FA0302AB
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#03750
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Nov 25, 2024Facades FISPHAZ
CYCLE 9C UNSAFE REPORT FILED
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 6:30 AM ET. BBL 4016410001.