| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 11, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED: TEMPORARY CONSTRUCTION EQUIPMENT FENCE IN PLACE. INSTALLED INADEQUATE JOB SITE FENCE GATE AT EXPOSURE # 1. CREATING UNSAFE CONDITIONS, EASY ACCESS TO JOB SITE GETTING SERIOUSLY I #39557759R | Oct 21, 2026 DEFAULT | $1,030 |
| Nov 25, 2025 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION OF A PROPOSED 7 STORY NEW BUILDING AT FOUNDATION PHASE, I OBSERVED NO FIRE EXTINGUISHERS ON SITE, UPON REQUEST NONE WAS PROVIDED. FAILURE TO PROVIDE FIRE EXTINGUISHERS AS PER FIRE C #39547356N | Dec 14, 2026 DEFAULT | $1,280 |
| Nov 25, 2025 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A PROPOSED 7 STORY NEW BUILDING AT FOUNDATION PHASE, I OBSERVED WORKERS DRILLING PILES, UPON REVIEW OF THE SITE SAFETY PLAN, PILE DRIVING MACHINE AND DEWATERING TANK WAS NOT ON T #39547355L | Dec 14, 2026 DEFAULT | $2,530 |
| Oct 29, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED CONSTRUCTION FENCE INSTALLED AT EXP# 1 NOT MAINTAINED AS PER CODE CONSTRUCTION FENCE NOT STRUCTURALLY STABLE. SWAYS ALSO LEAN INWARD. THIS CREATES A POTENTIAL HAZARD FOR COLLAPSED #39546494R | Feb 25, 2026 IN VIOLATION | $1,000 |
| Oct 29, 2025 | Unknown CLASS - 2 BC 3303.4.2 AT TIME OF INSPECTION OBSERVED DEBRIS CONTAINER OCCUPYING ROADWAY AT EXP#1 FILL TO NEAR THE RIM NOT COVERED AS PER CODE WHICH CREATE A RISK OR HAZARD FOR DEBRIS FALLING ONTO PUBLIC. #39546495Z | Feb 25, 2026 IN VIOLATION | $2,500 |
| Oct 29, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED JERSEY BARRIERS AT EXP#1 NOT AS PER MANUFACTURES SPECIFICATION. JERSEY BARRIERS NOT INTERLOCKED FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLOWING UNINTENDED MOVEMEN #39546496K | Feb 25, 2026 IN VIOLATION | $1,250 |
| Jul 1, 2025 | Construction CLASS - 2 AT TIME OF MY INSPECTION CONSTRUCTION OPERATION IN PROGRESS, I OBSERVED HOISTING AND RIGGING OPERATION VIA EXCAVATOR OVER PUBLIC WALKWAY AND SIDEWALK. I ALSO OBSERVED THAT THERE WERE NO FLAG PERSON, BARRIERS, S #39541839K | Feb 9, 2027 DEFAULT | $5,000 |
| Jul 1, 2025 | Unknown CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED WATER PUMP MACHINERY AND DUMPSTER STORED IN THE STREET AT EXPOSURE#1 WITHOUT ANY BARRIERS OR ENCLOSURES TO PROTECT PUBLIC FROM UNSAFE ACCESS OF MACHINERY.STOP ALL DELIVERIES #39541840H | Feb 9, 2027 DEFAULT | $5,000 |
| Jul 1, 2025 | Unknown CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED OBSTRUCTION ON STREET AND SIDEWALK INCLUDING HEAVY EQUIPMENT EXCAVATORS, DRILLS CROSSING SIDEWALK INTO JOBSITE. UPON REQUEST FOR D.O.T PERMIT AS REQUIRED FOR OCCUPYING AND C #39541838Z | Sep 10, 2025 DEFAULT | $5,000 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 11, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED: TEMPORARY CONSTRUCTION EQUIPMENT FENCE IN PLACE. INSTALLED INADEQUATE JOB SITE FENCE GATE AT EXPOSURE # 1. CREATING UNSAFE CONDITIONS, EASY ACCESS TO JOB SITE GETTING SERIOUSLY I | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)