4 floors · 4 apartments · 4,083 sq ft · built 2018 · class S4 · owner of record: Unavailable Owner
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 70 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 16, 2019 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED PLANS.AT TIME OF INSPECTION ON A ACTIVE JOBSITE IT WAS OBSERVED THAT EXTRA STEEL I-BEAM WAS INSTALLED AT EXP#1 GROUND FLOOR ABOVE WINDOW AND DOOR MISSING CONNECTION BETWEEN STE #35373393J | Aug 29, 2019 IN VIOLATION | $2,500 |
| Feb 16, 2019 | Construction CLASS - 1 3305.2.2=STRUCTUAL STEEL ASESEMBLY/FABRICATION.AT TIME OF INSPECTION ON A ACTIVE JOBSITE,IT WAS OBSERVED THAT STRUCTURAL STEEL INSTALLED THROUGHOUT JOBSITE HAS BEEN MODIFIED,CUT,TORCHED.UPON REQUEST FOR APPROVE #35373394L | Aug 29, 2019 IN VIOLATION | $2,500 |
| Oct 17, 2018 | Construction CLASS - 2 BC 3308.5 VERTICAL NETTING. AT TIME OF INSPECTION OF A 4 STORY NB CURRENTLY AT THE ROOF LEVEL. I OBSERVED MASONRY WORK BEEN CARRIED OUT AT EXPOSURE#4 LEADING EDGE AT ROOF LEVEL W/O VERTICAL NETTINGS IN CONTRARY #35367609Z | Oct 8, 2019 IN VIOLATION | $1,250 |
| Oct 17, 2018 | Construction CLASS - 1 28-105.12.8 WORK CONTRARY TO CONSTRUCTION DOCUMENTS. AT TIME OF INSPECTION OF A 4 STORY NB, CURRENTLY AT ROOF LEVEL I OBSERVED NEEDLE BEAMS USED FOR OVERHEAD PROTECTION AT EXPOSURE 2 WHEN REQUESTED TO SEE THE D #35367607P | Oct 8, 2019 IN VIOLATION | $2,500 |
| Oct 17, 2018 | Construction CLASS - 1 BC 3303.2.3.1 TEMPORARY LIGHTING. AT TIME OF MY INSPECTION, I OBSERVEDNO LIGHTING ON VARIOUS LEVEL(CELLAR-3 STORY). NO TEMP LIGHT WAS SETUP FOR FUTURE USE ON EVERY LEVEL. WORKER WERE TRAVELING THROUGHOUT THE SI #35367608R | Oct 8, 2019 IN VIOLATION | $2,500 |
| Aug 6, 2018 | Construction CLASS - 2 WORK DOES NOT CONFORM TO APPROVED DESIGN DOCUMENTS. AT TIME OF INSPECTION ON AN ACTIVE DOBSITE AT 2ND FL LEVEL, I OBSERVED A TRANSVERSAL STRUCTURAL STEEL BEAM INSTALLED NOT IN CONFORMANCE WITH APPROVED PLANS. R #35350680K | Mar 19, 2019 IN VIOLATION | $625 |
| Aug 30, 2017 | Construction CLASS - 1 WORK KOES OT CONFORM TO APPROVED CONSTUCTION DOCUMENTS.AT TIME OF INSPECTION NOTED ON PLANS THAT ADJOINING PROPERTY AT EXPO#3 REQUIRED TIE BACK AS PER PLAN,AT JOBSITE THERE ARE NO TIE BACKS INSTALLED CONTRACTOR #35266225R | Jul 12, 2018 IN VIOLATION | $500 |
| Aug 30, 2017 | Construction CLASS - 2 FAILURE TO PROVIDE WATER PROOFING AT TIME OF INSPECTION.NOTED:AT EXPOS#3/4 THAT WEATHER PROOFING WAS NOT PROVIDED AS PERM CODE REQUIREMENT.THEROSEAL AND PARGING.REM:COMPLY WITH CODE PROVIDE THEROSEAL AND PARGIN #35266226Z | Jul 12, 2018 IN VIOLATION | $800 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 12:14 AM ET. BBL 4016190014.