Manhattan · Block 162 · Lot 1 · 10038

1 Chatham Square

12 floors · 51,837 sq ft · built 1977 · class O6 · owner of record: Wing Ming Propertiesusa

39open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
191dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 51,837 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 191 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 191 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 801 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $308,750 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 853 days
Filing window not open yet
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 162). Agency page

Dec 31, 2032
in 2262 days
Next due 2032
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-30 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7)
IssuedViolationHearingBalance
Oct 19, 2022Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQ CYCLE8C REPORT OF CRITICAL EXAM DOC CONDITION OF EXTERIOR WALL&APPURTENANCES REQ BY 28-302.4 FOR CONTROL800366.SUBMIT ACCEPTABLE REQ TECH REPORT
#37022930Y
Feb 9, 2023
IN VIOLATION
$0
Jun 20, 2017Unknown CLASS - 2
FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 100002000 HAS BEEN INSPECTED,TESTED,AND DISINFECTED AND THAT A MAINTENANCE PLAN HAS BEEN DEVELOPED AND IMPLEMENTED BY NOVEMBER,1,2016.REM:FILE ANNUAL CERT
#37003593Z
Jan 25, 2018
IN VIOLATION
$0
Jan 25, 2011Construction CLASS - 2
FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEWITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28.302 & THE DEPT OF BUILDINGS RULES &
#36015730H
Jun 2, 2011
IN VIOLATION
$0
Mar 29, 2010Construction CLASS - 2
FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEWITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28.302 & THE DEPT OF BUILDINGS RULES &
#36012679H
Dec 2, 2010
IN VIOLATION
$0
Jul 23, 2009Cranes and Derricks CLASS - 1
INADEQUATE SAFETY MEASURES: OPERATION OF HOISTING EQUIPMENT IN UNSAFE MANNER. NOTED: SINGLE POINT ROPE CHAIR BEING OPERATED AT EXP #1. NO ROPE SCAFFOLDS CAN BE USED OVER 100' HIGH. 1 ELEVEN STORY BLDG. REMEDY:
#34787833H
Jul 15, 2010
IN VIOLATION
$0
Jul 23, 2009Construction CLASS - 1
FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. NOTED: SCAFFOLD BEING USED TO WASH WINDOWS AT EXP #1 BUSY STREET BOWERY MOTT IN FRONT OF CITI BANK DOOR. THERE IS NO PROTECTION
#34787834J
Jul 15, 2010
IN VIOLATION
$0
Nov 21, 2008Construction CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28.302 AND THE DOB RULES AND REGULATIONS
#36001051Z
Apr 16, 2009
IN VIOLATION
$0
DOB (16)
IssuedViolationStatus
Sep 3, 2019SPRINKLER
FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019
#NRF00365
DOB VIOLATION - ACTIVE
Aug 17, 2015CONSTRUCTION
DUE TO MOTOR VEHICLE STRIKING SIDE WALK SHED STEEL COLUMN
#CNE01TV
DOB VIOLATION - ACTIVE
Mar 1, 2013LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
#00059
DOB VIOLATION - ACTIVE
Mar 1, 2013LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
#00058
DOB VIOLATION - ACTIVE
Oct 1, 2012ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
#00107
DOB VIOLATION - ACTIVE
May 3, 2012FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00058
DOB VIOLATION - ACTIVE
Jan 1, 2012FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00042
DOB VIOLATION - ACTIVE
Dec 13, 2011ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
#00110
DOB VIOLATION - ACTIVE
Nov 30, 2007LOCAL LAW 11/98 - FACADE

#NRF42003
DOB VIOLATION - ACTIVE
Dec 19, 2003ELEVATOR

#9013/188795
DOB VIOLATION - ACTIVE
Mar 26, 2002LOCAL LAW 62/91 - BOILERS

#00143
DOB VIOLATION - ACTIVE
Mar 26, 2002LOCAL LAW 62/91 - BOILERS

#00142
DOB VIOLATION - ACTIVE
Mar 16, 1999LOCAL LAW 62/91 - BOILERS

#00140
DOB VIOLATION - ACTIVE
Mar 16, 1999LOCAL LAW 62/91 - BOILERS

#00141
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#04813
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#04812
DOB VIOLATION - ACTIVE
DOB NOW Safety (16)
IssuedViolationStatus
Sep 3, 2019Sprinklers FTF-SP-FINAL
Active
Mar 1, 2013Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
Active
Mar 1, 2013Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
Active
Oct 1, 2012Elevators EVCAT1
Active
Oct 1, 2012Elevators EVCAT1
Active
May 3, 2012Benchmarking - LL84 FTF-EN-BENCH
Active
Jan 1, 2012Benchmarking - LL84 FTF-EN-BENCH
Active
Dec 13, 2011Elevators EVCAT1
Active
Dec 13, 2011Elevators EVCAT1
Active
Nov 30, 2007Facades LL1198
CYCLE 6 NO REPORT FILED
Active
Mar 26, 2002Boiler LL6291
Active
Mar 26, 2002Boiler LL6291
Active
Mar 16, 1999Boiler LL6291
Active
Mar 16, 1999Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 4:48 PM ET. BBL 1001620001.