Brooklyn · Block 6866 · Lot 41 · 11214

1 Bay 38 Street

3 floors · 6 apartments · 3,510 sq ft · built 1924 · class S9 · owner of record: 2468 86th St, Llc

45open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
52dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 52 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 52 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 68 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 296 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 417 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-05 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (3)
IssuedViolationHearingBalance
Nov 5, 2009Unknown CLASS - 2
FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A CERT. OF CORRECTION FOR ECB#34755165P ISSUED ON 06/22/2009, FOR FAILURE TO MAINTAIN EXTERIOR BLDG WALL@ 3RD FLR.WINDOW,NORTH WALL, APPROX. 4'X8'X1/4"STUCCO
#34810501Y
Dec 28, 2009
IN VIOLATION
$0
Dec 15, 1991Construction Non-Hazardous
FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: APPROX. 4 FOOT SECTION OF METAL CORNICE IS DEFECTIVE AND HANGING DOWN REMEDY: MAKE LAWFUL REPAIR FORTHWITH.
#34036213J
May 4, 1992
WRITTEN OFF
$0
Jun 4, 1991Construction Non-Hazardous
FAILURE TO MAINTAIN EXTERIOR BUILDING WALL DEFECT IS:LOOSE METAL CORNICE AT WEST EXTERIOR PARAPIT WALL. REMEDY:MAKE ALL NECESSARY REPAIRS TOTHE SATISFACTION OF THIS DEPT PROVIDE ALL NECESSARY PROTECTION OF PUBL
#34050818N
Oct 7, 1991
WRITTEN OFF
$0
DOB (7)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#13911
DOB VIOLATION - ACTIVE
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#30649
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#31639
DOB VIOLATION - ACTIVE
Jun 1, 1994LOCAL LAW 62/91 - BOILERS

#16991
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#30670
DOB VIOLATION - ACTIVE
Jun 1, 1993LOCAL LAW 62/91 - BOILERS

#16990
DOB VIOLATION - ACTIVE
May 30, 1991CONSTRUCTION

#NERH01
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 10, 1997Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
Jun 1, 1994Boiler LL6291
Active
Jun 1, 1993Boiler LL6291
Active
HPD (30) · C 2 · B 19 · A 9
IssuedClassViolationCorrect by
Sep 13, 2010BApt 2RT · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 2RT, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 18, 2010
Sep 13, 2010BApt 2RT · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE HINGES AT CLOSET DOOR AT SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2RT, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 18, 2010
Sep 13, 2010BApt 2RT · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHENETTE LOCATED AT APT 2RT, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 18, 2010
Sep 13, 2010BApt 2RT · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHENETTE LOCATED AT APT 2RT, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 18, 2010
Sep 13, 2010BApt 2RT · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 2RT, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 18, 2010
Sep 13, 2010BApt 2RT · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE VANITY AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2RT, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 18, 2010
Aug 30, 2010B§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND LOCK ASSEMBLY TO BUILDING ENTRANCE DOOR , 1st STORYOct 4, 2010
Aug 30, 2010B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WALLS AND CEILING, CONSISTING OF FIRE RETARDANT MATERIAL AT PUBLIC HALL, 1st STORYOct 4, 2010
Aug 30, 2010A§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MAILBOXES AT PUBLIC HALL, 1st STORYDec 3, 2010
Aug 4, 2009B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK AT CEILING AT PUBLIC HALL, 1st STORYSep 8, 2009
Aug 4, 2009B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING (PLASTER) CEILING AND SOUTH WALL AT PUBLIC HALL, 1st STORYSep 8, 2009
Aug 4, 2009A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND SOUTH WALL AT PUBLIC HALL, 1st STORYNov 7, 2009
Jun 12, 2008A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PARTITION ERECTED 3 STY PUBLIC HALL CREATING 2 APTS.Sep 15, 2008
Jun 12, 2008BD26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 50 WATTS.Jul 17, 2008
Jun 12, 2008A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING.Sep 15, 2008
Jun 12, 2008BD26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES KITCHEN 3RD STY APT.Jul 17, 2008
Jun 12, 2008BD26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES THRU OUT 3 STY APT.Jul 17, 2008
Jun 12, 2008BD26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING FIXTURES PRESENT LIGHTS NOT ON NIGHT INSPECTION 100 WATTS REQUIRED.Jul 17, 2008
Jun 12, 2008BD26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION PUB HALL ALL STYS ER1.Jul 17, 2008
Jun 12, 2008A§ 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE SOUTHEAST ROOF.Sep 15, 2008
Jun 12, 2008AD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCARDED BIKES ROOF CENTER.Sep 15, 2008
Jun 12, 2008AD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING 3 STY WEST APT BATHROOM.Sep 15, 2008
Jun 12, 2008BD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING 3 STY PUBLIC HALL.Jul 17, 2008
Jun 12, 2008AD26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS ALL STYS PUBLIC HALL.Sep 15, 2008
Jun 12, 2008CD26-17.10 ADM CODE PROVIDE READY ACCESS TO BUILDING'S HEATING SYSTEM CELLR DOOR LOCKED.Jun 18, 2008
Jun 12, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUB HALL AND ON BOILER ROOM DOOR.Jun 18, 2008
Jul 28, 2006A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOORS ALL STORIES, AT PUBLIC HALLNov 24, 2006
Jul 3, 2002B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , UNKEYED PLASTER AT CEILING, AT PUBLIC HALL, 1st STORYAug 12, 2002
Jul 3, 2002BApt 2RR · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR , DEFECTIVE (MRS.MUNOZ), IN THE ENTIRE APARTMENT LOCATED AT APT 2RR, 2nd STORY, APARTMENT AT NORTHAug 12, 2002
Jul 3, 2002BApt 2RR · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN , ROACHES, IN THE ENTIRE APARTMENT LOCATED AT APT 2RR, 2nd STORY, APARTMENT AT NORTHAug 12, 2002

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 9, 2026, 2:34 PM ET. BBL 3068660041.

Look up another building