Queens · Block 15861 · Lot 35 · 11691

1-80 Beach 35 Street

3 floors · 39,025 sq ft · built 1931 · class W1 · owner of record: Nyc Department Of Education

18open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
172dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 51 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 39,025 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 172 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 172 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 416 days
Next cycle year 2027
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-10 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (16)
IssuedViolationHearingBalance
Apr 2, 2026Construction CLASS - 2
REISSUED ECB #35693157K. EXIT DOOR NOT SELF-CLOSING. NOTED AT 4TH FLOOR BULKHEAD AT STAIR B AND 1ST FLOOR EXIT #2 DOORS NOT SELF-CLOSING. REMEDY: REPAIR/REPLACE DOOR.
#35727408Z
May 15, 2026
POP/IN-VIO
$0
Apr 2, 2026Construction CLASS - 2
REISSUED ECB #35693161N. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT 3RD FLOOR ROOM 311 RUNNING CRACKS INSIDE BETWEEN 2ND AND 3RD FLOOR STAIRWAY AND AT CELLAR AND 1ST FLOOR STAIRWAY A SPALLI
#35727405N
May 15, 2026
POP/IN-VIO
$0
Apr 2, 2026Construction CLASS - 2
REISSUE ECB #35693159Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED AT CELLAR ELECTRICAL ROOM FLOOR AND BASE OF WALL THROUGHOUT WATER PENETRATION AND DISREPAIR. REMEDY: REPAIR AND/OR REPLACE.
#35727406P
May 15, 2026
POP/IN-VIO
$0
Apr 2, 2026Construction CLASS - 2
REISSUED ECB #35693163R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT BULKHEAD STAIR B INTERIOR WALLS AND AROUND DOOR SPALLING PLASTER AND CRACKS. REMEDY: REPAIR AND/OR REPLACE.
#35727403J
May 15, 2026
POP/IN-VIO
$0
Apr 2, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED EMERGENCY LIGHT BY EXIT #5 NOT WORKING. REMEDY: REPAIR/REPLACE LI
#35727401X
May 15, 2026
POP/IN-VIO
$0
Apr 2, 2026Construction CLASS - 2
REISSUED ECB #35693162P. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT ROOMS 315, 316, 216 AT CEILINGS WATER PENETRATIONS.REMEDY: REPAIR AND/OR REPLACE.
#35727404L
May 15, 2026
POP/IN-VIO
$0
Apr 2, 2026Construction CLASS - 2
REISSUED ECB #35693158M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED SEVERAL SMOKE DOORS NOT SELF-CLOSING: AT 3RD FLOOR ROOM 316, 2ND FLOOR ROOM 216, 1ST FLOOR MULTI PURPOSE ENTRANCE LEFT AND C
#35727407R
May 15, 2026
POP/IN-VIO
$0
Apr 8, 2025Construction CLASS - 2
REISSUE #35678759M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT ROOMS 315 AND 316 CEILINGS ARE IN DIREPAIR ROOF LEAKING WATER PENETRATION. REMEDY: REPAIR AND/OR REPLACE ROOF.
#35693162P
May 6, 2025
POP/IN-VIO
$0
Apr 8, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT BULKHEAD STAUR B INTERIOR WALL AND AROUND DOOR SPALLING AND CRACKS, EXTERIORELECTRICAL BOX RUSTED. REMEDY: REPAIR AND/OR REPLACE
#35693163R
May 6, 2025
POP/IN-VIO
$0
Apr 8, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT 3 FLOOR ROOM 316, 2FL. 216, 1 FLOOR MULTI PURPOSE ENTRANCE LEFT AND CAFETERIA BY EXIT 1 DOORS ARE NOT CLOSING PROPERLY. REMEDY: REPAIR AND/OR REPL
#35693158M
May 6, 2025
POP/IN-VIO
$0
Apr 8, 2025Construction CLASS - 2
REISSUE #35678760J. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT 3 LFOOR ROOM 311 OUTSIDE WALL RUNNING CRACKS, BETWEEN 2ND AND 3RD FL. STAIRWELL A AND CELLAR AND 1ST FLOOR STAIRWELL A SPALLIN
#35693161N
May 6, 2025
POP/IN-VIO
$0
Apr 8, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT CELLARELECTRICAL ROOM FLOOR AND BASE OF WALL THROUGHOUT WATER PENETRATION AND DISREPAIR. REMEDY: REPAIR AND/OR REPLACE WALLS AND FLOORS.
#35693159Y
May 6, 2025
POP/IN-VIO
$0
Apr 8, 2025Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING. NOTED AT 4 FLOOR BULHEAD AT STAIR B AND CELLAR SMOKE EXIT 2 DOORS ARE NOT CLOSING PROPERLY. REMEDY: REPAIR AND/OR REPLACE DOORS.
#35693157K
May 6, 2025
POP/IN-VIO
$0
Apr 23, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT 3RD FLOOR PRINCIPAL ROOM#311,STOP CRACK IN THE WALL APPROX.6' CRACK AT STAIRWAY A BY WINDOW,AT EXIT#2 VERTICAL CRACK(3)IN THE WALL.REM:MAKE NECESSA
#35678760J
Jul 2, 2024
POP/IN-VIO
$0
Apr 23, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES-NOTED: AT CELLAR, FOUNDATION WALLS HAVE BECOME POROUS ALLOWING THE RAIN WATER INTO THECELLAR, ELECTRICAL ROOM AND GAS METER ROOM. WATER ALSO SEEP THROUGH TH
#35678757Z
Aug 20, 2024
POP/IN-VIO
$0
Apr 23, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: WATER PENETRATION IN CLASS ROOM #316 DUE TO DEFFECTIVE ROOF. REMEDY: MAKE NECESSARY REPAIRS.
#35678759M
Aug 20, 2024
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (2)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 10, 2026, 4:07 AM ET. BBL 4158610035.